2 ECOnomy’s EcoFC-AM™ series PEM fuel cell stacks are designed for demonstration and study of fuel cell operation. Data Sheet Parameters by model >
Model (No. of cells is indicated by the last digit) Nominal Power Approximate Dimensions Recommended gas flow rates (SLPM) (w/o bolts, fittings, and current collectors) H 2 Air EcoFC-1AM 3.2 W @ 0.6 V 9 x 9 x 3 cm 0.04 0.65 EcoFC-2AM 6.5 W @ 1.2 V 9 x 9 x 3.5 cm 0.085 1.3 EcoFC-3AM 10 W @ 1.8 V 9 x 9 x 4 cm 0.13 1.95 EcoFC-4AM 13 W @ 2.4 V 9 x 9 x 4.5 cm 0.17 2.5 EcoFC-5AM 16 W @ 3.0 V 9 x 9 x 5 cm 0.2 3.1 EcoFC-6AM 20 W@ 3.6 V 9 x 9 x 5.5 cm 0.25 3.7 General operational parameters and conditions Maximum output voltage (w/o load) 0.9 V per cell >
*
Recommended gas pressures (gauge) 1 bar for both H >
2 and Air Maximum gas pressures (each channel) 1.5 bar gauge Allowable pressure difference between the two channels 0.1 bar Acceptable ambient temperature 0 to +50 C Stack working temperature 65-70 C Stack maximal temperature Up to 80 C Fuel / Oxidant Hydrogen / Air >
**
Optimal working conditions for achieving nominal output. 99.99% (or more) purity of H >
2 gas, 100% humidity of gases >
***
* It is strongly recommended to keep the loaded voltage higher than 0.5V on each cell. ** It is strongly recommended NOT to use pure oxygen instead of air, as it may cause damage of the MEAs, due to high activity of the catalyst. *** Operation at lower temperatures and lower humidity (RH) of gases is also possible, although with loss of performance.