You may also be interested in
Bow-type handle, Concealed hinge, Damper, Handle, Fitting
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:6.00pt "Arial", sans-serif; }
.font1 { font:7.00pt "Arial", sans-serif; }
.font2 { font:10.00pt "Arial", sans-serif; }
.font3 { font:11.00pt "Arial", sans-serif; }
.font4 { font:6.00pt "Tahoma", sans-serif; }
800-3-HINGES • FAX 631-737-2933
DAMPERS
Gas springs apply a controlled force and dampers control an external force. One or the other will satisfy any lid or door control situation.
Dampers are used primarily where a heavy load or door must be lowered or swung in a controlled motion at a constant speed. For example, dampers prevent a door from slamming shut or swinging wildly open.
TWO STANDARD TYPES
Two types of standard dampers are available, depending on the physical position in which they are to be used:
• Compression dampers provide controlled speed in the compressive direction.
• Extension dampers provide controlled speed in the extensive direction.
HOW DAMPERS WORK
Guden dampers are similar in appearance and construction to our Guden Gas Springs, except:
(1) The tube is filled with hydraulic oil instead of non-hazardous nitrogen.
(2) Dampers are force-absorbing instead of force-supplying. The oil inside the damper must pass through an orifice plate, thus controlling speed.
DAMPERS INSTALLATION/OPERATING TIPS
Compression dampers operate best in the shaft up position so that the internal piston remains in the oil. The lid or door should be closed before full compression is reached.
Extension dampers work best in the shaft down position. An extension damper is an excellent end-of-motion stop with appropriate end fittings: metal for heavier loads, plastic for lighter loads.
SELECTING THE RIGHT DAMPER
As with Guden Gas Springs, size of load, weight of load, direction of motion and location of mounting points determine the correct size. Guden dampers are available in rod/tube diameter sizes .24" x .59" and .32" x .87", with stroke lengths from 2" to 7", extended lengths from 7.89" to 19.65" and maximum load capacities from 50 lbs. to 100 lbs.
CUSTOM DAMPERS
We can custom make almost any size damper to suit your application. Dampers are available on special order with custom damping rates, and also double damped in both compression and extension.
STOCK PART NUMBERS AND SIZES (See page 50 for end fittings)
Stock Part Number
Extended
Rod
Tube
Minimum
Maximum
Orifice Plate Damping Identification
Length'
Stroke
Dia.
Dia.
Load
Load
Heavy
Med. Heavy
Medium
Med.Light
Light
Compression
Extension
(Inches)
(Inches)
(Inches)
(Inches)
(lbs.)
(lbs.)
Damping
Damping
Damping
Damping
Damping
GDC50
GDE50
7.89
2
.24
.59
3
50
C
J
D
N
E
GDC51
GDE51
10.02
3
.24
.59
3
50
C
J
D
N
E
GDC52
GDE52
12.50
4
.24
.59
3
50
C
J
D
N
E
GDC53
GDE53
15.02
5
.24
.59
3
50
C
J
D
N
E
GDC60
GDE60
12.24
4
.315
.87
20
100
J
D
E
F
S
GDC61
GDE61
14.49
5
.315
.87
20
100
J
D
E
F
S
GDC62
GDE62
17.01
6
.315
.87
20
100
J
D
E
F
S
GDC63
GDE63
19.65
7
.315
.87
20
100
J
D
E
F
S
Note: The complete part number consists of the Stock Part Number (above) plus the Orifice Plate Damping Identification (above) and the end fitting you require (see page 50), i.e., GDC50-D-K. The I*, K and Fat Blade end fittings are stock.
* Extended length is .24" longer with the "I" end fitting. 49
|
|