video corpo

UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML)
52Pages

{{requestButtons}}

Catalog excerpts

UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 1

GRUNDFOS DATA BOOKLET UPML, UPMXL UPML GEO, UPMXL GEO, SOLAR PML 1 x 230 V 50/60 Hz

Open the catalog to page 1
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 2

Ecodesign regulation in brief 4 Digital low voltage PWM signal 8 8. Performance curves and technical data 22 REACH compliancy - Chemical Management -Grundfos Focus List 48 Declaration concerning GRUNDFOS' compliance with RoHS and WEEE directive 48

Open the catalog to page 2
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 3

1. General data Introduction This data booklet applies to the Grundfos UPML and UPMXL product ranges: • UPML XX-95 AUTO • UPML XX-105 PWM • UPML GEO XX-105 PWM • UPMXL XX-105 AUTO • UPMXL GEO XX-125 PWM • SOLAR PML XX-145 PWM. Applications The UPML, UPMXL circulator pumps are designed for circulating liquids in heating and air-conditioning systems with variable flows, where the pump is remote controlled via low-voltage PWM signal or internally controlled via AUTO user interface. Speed control can reduce the power consumption considerably. In addition, speed control is required to control...

Open the catalog to page 3
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 4

General data SOLAR PML • Optimised for matched-flow solar thermal systems in terms of performance and robustness • to be controlled via digital pulse-width modulation (PWM) low-voltage signal (profile SOLAR) • fits into existing systems with the SOLAR PM2 pump, no expanded space requirements, possible use of existing pump housings, electrical compatibility with existing PWM solar controllers and no ambient-temperature constraints (EN 60335) • suitable for solar media containing glycol up to 110 °C peak. Benefits • The pump uses up to 80 % less electrical power than conventional...

Open the catalog to page 4
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 5

UPML, UPMXL General data Identification Type key UPM Example UPM XL 25 -105 180 Type range XL: 180 W Nominal diameter (DN) of suction and discharge ports [mm] = cast-iron pump housing (no letter) N = stainless-steel pump housing 6 Rated current [A] at maximum and minimum performance 7 Input power P1 [W] at maximum and minimum performance 8 Speed 10 Direction of rotation 11 Product number 12 Production code (YYWW) 16 Temperature class 17 Maximum system pressure [MPa] 18 Energy index 19 Customer item number

Open the catalog to page 5
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 6

UPML, UPMXL General data Performance range H [m] SOLARPML XX 145

Open the catalog to page 6
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 7

2. Product range UPML, UPMXL 1 x 230-240 V, 50/60 Hz Pump type Port-to-port length Connection pipe [mm] thread Control signal Data sheet page

Open the catalog to page 7
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 8

Control mode and signals 3. Control mode and signals The UPML, UPMXL and SOLAR pumps are controlled via a digital low-voltage pulse-width modulation (PWM) signal which means that the speed of rotation depends on the input signal. The speed changes as a function of the input profile. Digital low voltage PWM signal Signal The PWM signal is a square wave pulse width modulated signal designed to the frequency range 100-4000 Hz. The PWM signal is used to select the speed (speed command) and as feedback signal. The PWM frequency of the feedback signal is fixed at 75 Hz in the pump. Duty cycle d %...

Open the catalog to page 8
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 9

PWM input signal profile HEATING Input signal profile HEATING for heating and geothermal applications At high PWM signal percentages (duty cycles), a hysteresis prevents the pump from starting and stopping if the input signal fluctuates around the shifting point. At low PWM signal percentages, the pump speed is high for safety reasons. In case of a cable breakage in a gas boiler system, the pumps will continue to run at maximum speed to transfer heat from the primary heat exchanger. This is also suitable for heating pumps to ensure that the pumps transfer heat in case of a cable breakage....

Open the catalog to page 9
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 10

Control mode and signals UPML, UPMXLPWM input signal [%] Pump status s 5 Standby mode: Off > 5 / s 8 Hysteresis area: On/off > 8 / s 15 Minimum speed: Min. (pump is running at minimum speed) PWM feedback signal A PWM feedback signal provides information about the current performance of the pump, such as current power consumption or various alarm or warning modes. See figures 5 or 6. Alarms Alarm output signals are available. Some PWM output signals are dedicated to alarm information. If the supply voltage is measured to a value below 195 V, the output signal is set to 75 %. If,...

Open the catalog to page 10
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 11

PWM feedback signal - flow estimation Alarms Alarm output signals are available. Some PWM output signals are dedicated to alarm information. If the supply voltage is measured to a value below 195 V, the output signal is set to 75 %. If, at the same time, the rotor is locked due to deposits in the hydraulics, the output signal is set to 90 %, as this alarm is given a higher priority. Flow estimation The PWM feedback signal can be used to measure the flow of the pump. Control mode and signals UPML, UPMXL STANDBY (Stop) ALARM Stop: BLOCKED ERROR ALARM Stop: ELECTRICAL ERROR WARNING: ELECTRONIC...

Open the catalog to page 11
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 12

Control mode and signals User interface AUTO versions The UPML AUTO, UPMXL AUTO pumps are internally controlled. Via user interface it is possible to select two control modes with three curves each: Proportional pressure Proportional pressure mode offers the best energy savings. The maximum head (differential pressure) of the pump curve will be reached at the maximum performance curve of the pump. The speed will be automatically reduced at reduced flow to minimum 50 % of the maximum head at zero flow. Constant pressure/power Constant pressure/power mode limits the maximum power consumption...

Open the catalog to page 12
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 13

UPML, UPMXL 4. Construction Exploded view UPML, UPMXL and SOLAR

Open the catalog to page 13
UPML, UPMXL (UPML GEO, UPMXL GEO, SOLAR PML) - 14

UPML, UPMXL Construction Sectional drawing Description of components The UPML, UPMXL is of the canned-rotor type, i.e. pump and motor form an integral unit without shaft seal and with only one gasket for sealing and four screws for fastening the stator housing to the pump housing. The bearings are lubricated by the pumped medium. The focus has been on using eco-friendly materials as well as on limiting the number of materials. AISI/ ASTM Spacer Control box and cooling cover Heat sink with cooling pad Radial bearing Nameplate Stator housing Stator Air-venting/ de-blocking screw O-ring Copper...

Open the catalog to page 14

All GRUNDFOS catalogs and technical brochures

  1. A WIDE RANGE

    60 Pages

  2. ALPHA1 L

    2 Pages

  3. DME

    2 Pages

  4. UPM3

    92 Pages

  5. GRUNDFOS UPM3

    11 Pages

  6. CRN MAGdrive

    2 Pages

  7. GRUNDFOS CRE

    2 Pages

  8. TPE3

    7 Pages

  9. CIM/CIU

    3 Pages

  10. BMS

    5 Pages

  11. BM

    2 Pages

  12. BACMON

    16 Pages

  13. AQtap

    7 Pages

  14. ALPHA2 L OEM

    19 Pages

  15. A WIDE RANGE

    60 Pages

  16. CRE GRUNDFOS

    2 Pages

  17. MTA

    3 Pages

  18. Unilift CC

    2 Pages

  19. ALPHA1

    2 Pages

  20. AMD-AMG-AFG

    3 Pages

  21. HS

    5 Pages

  22. SQ

    3 Pages

  23. MAGNA/UPE

    12 Pages

  24. Selcoperm SES

    20 Pages

  25. Conex DIS-G

    2 Pages

  26. Conex DIS-C

    2 Pages

  27. Sololift2

    9 Pages

  28. VGA and VGB

    28 Pages

  29. Oxiperm Pro

    8 Pages

  30. DMX

    18 Pages

  31. DMH

    18 Pages

  32. MP 204

    3 Pages

  33. TP/TPE

    5 Pages

  34. SP Product

    7 Pages

  35. S-Tube

    4 Pages

  36. SB & SBA

    8 Pages

  37. Multilift

    21 Pages

  38. KPL and KWM

    3 Pages

  39. Grundfos GO

    3 Pages

  40. DW

    12 Pages

  41. DIP

    16 Pages

  42. NEW ALPHA2

    7 Pages

  43. GRUNDFOS DWK

    3 Pages

  44. GRUNDFOS DP

    5 Pages

  45. DME, DMS, DDI

    14 Pages

  46. Diffuser

    3 Pages

  47. CR monitor

    8 Pages

  48. Control MPC

    4 Pages

  49. CMV

    8 Pages

  50. CIM / CIU

    3 Pages

  51. BMP

    9 Pages

Archived catalogs