SMART Digital ? DDA, Profibus - 2 Pages

Add to MyDirectIndustry favorites
SMART Digital ? DDA, Profibus

Catalog excerpts

grundfos communication interfaces SMART Digital – DDA with Profibus DP / Modbus RTU / PROFINET IO / Modbus TCP – for industrial automation The SMART Digital dosing pump range DDA is available with an E-box which hold a CIM 150 Profibus -DP interface. This is a standard interface for data transmission between a Profibus DP network and a Grundfos pump. It makes data exchange possible between Grundfos DDA and a PLC or SCADA system. An E-Box version for Modbus enable a communication with the Modbus RTU protocol. With the external CIU 500 module it is possible to communicate via PROFINET IO or Modbus TCP protocol to the DDA. No custom programming is needed to integrate the CIM 150 in a Profibus network. System integration is very straight-forward with standard GSD file. The communication box ( E-box) can be installed later (retrofit installation). When connecting the DDA to the E-box you only have to connect the internal GENIbus by wire between pump and E-box. Via the Display on the DDA you can easily set the bus address. For each DDA an own E-box is required. Supported products > DA Control variant FCM D > DDA Control variant FC > DA Control variant AR D Advantages at a glance > Remote control and monitoring of DDA SMART Digital dosing pump > ntegration into industrial automation systems (PLC; SCADA) I > Modular design – prepared for future needs > Retrofit of E-box possible > Easy installation and commissioning > The IP65 data cable inputs ensures reliable protection in harsh

 Open the catalog to page 1

DDA E-Box Data points Control Mode (Manual, Pulse, Analogue, Timer, Batch) Set Batch Dosing Time Set Flow Monitor Pressure Alarm Limit Relay Control of Relay 1 and 2 Operating Mode Status Actual Flow Monitor Pressure Alarm Limit Setting Control Source ( HMI, External, Bus) Fault & Warning Code Warning Status Bits Actual Date & Time Resulting Dosing Capacity Setpoint Remaining Dosing Volume Total Dosed Volume Volume Trip Counter Actual Analog Output Signal Digital Outputs Stroke Counter Time To Next Dosing Digital Inputs Analog Input Signal Pulse Input Frequency Measured Dosing Capacity...

 Open the catalog to page 2

All GRUNDFOS catalogs and technical brochures

  1. ALPHA1 L

    2 Pages

  2. DME

    2 Pages

  3. UPM3

    92 Pages

  4. GRUNDFOS UPM3

    11 Pages

  5. PUST 1700 RANGE

    3 Pages

  6. Grundfos LiqTec

    2 Pages

  7. CRN MAGdrive

    2 Pages

  8. GRUNDFOS CRE

    2 Pages

  9. TPE3

    7 Pages

  10. CM, CME

    7 Pages

  11. CIM/CIU

    3 Pages

  12. BMS

    5 Pages

  13. BM

    2 Pages

  14. BACMON

    16 Pages

  15. AQtap

    7 Pages

  16. ALPHA2 L OEM

    19 Pages

  17. A WIDE RANGE

    60 Pages

  18. CRE GRUNDFOS

    2 Pages

  19. MTA

    3 Pages

  20. Unilift CC

    2 Pages

  21. ALPHA1

    2 Pages

  22. AMD-AMG-AFG

    3 Pages

  23. HS

    5 Pages

  24. SQ

    3 Pages

  25. MAGNA/UPE

    12 Pages

  26. Selcoperm SES

    20 Pages

  27. Conex DIS-G

    2 Pages

  28. Conex DIS-C

    2 Pages

  29. Sololift2

    9 Pages

  30. VGA and VGB

    28 Pages

  31. Oxiperm Pro

    8 Pages

  32. DMX

    18 Pages

  33. DMH

    18 Pages

  34. MP 204

    3 Pages

  35. TP/TPE

    5 Pages

  36. SP Product

    7 Pages

  37. S-Tube

    4 Pages

  38. SB & SBA

    8 Pages

  39. HOME AND GARDEN

    52 Pages

  40. Multilift

    21 Pages

  41. KPL and KWM

    3 Pages

  42. Grundfos GO

    3 Pages

  43. DW

    12 Pages

  44. DIP

    16 Pages

  45. NEW ALPHA2

    7 Pages

  46. GRUNDFOS DWK

    3 Pages

  47. GRUNDFOS DP

    5 Pages

  48. DME, DMS, DDI

    14 Pages

  49. Diffuser

    3 Pages

  50. CUE E-SOLUTIONS

    12 Pages

  51. CR monitor

    8 Pages

  52. Control MPC

    4 Pages

  53. CMV

    8 Pages

  54. CM, CME Booster

    52 Pages

  55. CIM / CIU

    3 Pages

  56. BMP

    9 Pages

Archived catalogs