Conex DIS-G - 1

grundfos Water Treatment Conex® DIA-G, DIS-G gas warning systems Monitoring parameters: Cl2, ClO2, O3, NH3 and HCl Conex® DIA-G gas warning system Conex® DIS-G gas warning system The Conex® DIA-G (Dosing Instrumentation Advanced-Gas) safety system monitors gas dosing installations and gas storage rooms. The Conex® DIS-G (Dosing Instrumentation Standard-Gas) safety sytem monitors gas dosing installations and storage rooms. Features • Monitoring of two different gas storage rooms or two different gases at the same time • Simultaneous display of both measured values • Optimum safety due to permanent sensor monitoring, alarm relay and optional backup operation by connection of an external buffer battery • Very short response time in case of a sudden change of the gas concentration • Long and maintenance-free sensor service life • Sensor recognition and auto-calibration as well as monitoring of sensor life • Separate sensor interface for one potentiostatic sensor. When using the separate sensor interface, the Conex® DIA-G can be installed in a control room at a distance of up to 500 m from the sensor interface • With optional audible and visual alarm device • Display languages: German, English, French, Spanish, Polish and Russian Features • Monitoring of two gases at the same time • Simultaneous display of both measured values • Optimum safety thanks to the automatic sensor test function • Very short response time in case of a sudden change of the gas concentration • Long and maintenance-free sensor service life • With optional audible and visual alarm device • Display languages: German, English and French Monitoring parameters • Chlorine • Chlorine dioxide • Ozone • Ammonia • Hydrochloric acid Monitoring parameters • Chlorine • Chlorine dioxide • Ozone

Open the catalog to page 1
Conex DIS-G - 2

Technical data Electronics Backlit plain-text display Indication mode In ppm for measured values of both sensors In ppm for measured values of both sensors Relay outputs Five potential-free relay-outputs per software, switchable to NO (normally open) or NC (normally closed) (fail-safe); max. 250 V/6 A, max. 550 VA Five potential-free relay-outputs; max. 250 V/6 A, max. 550 VA ohmic load Signal inputs · Two measured value inputs (for amperometric sensors 1 and 2) · Internal CAN bus, including connections for two Interfaces, each for the operation of one potentiostatic sensor Two measured...

Open the catalog to page 2

All GRUNDFOS catalogs and technical brochures

  1. A WIDE RANGE

    60 Pages

  2. ALPHA1 L

    2 Pages

  3. DME

    2 Pages

  4. UPM3

    92 Pages

  5. GRUNDFOS UPM3

    11 Pages

  6. CRN MAGdrive

    2 Pages

  7. GRUNDFOS CRE

    2 Pages

  8. TPE3

    7 Pages

  9. CIM/CIU

    3 Pages

  10. BMS

    5 Pages

  11. BM

    2 Pages

  12. BACMON

    16 Pages

  13. AQtap

    7 Pages

  14. ALPHA2 L OEM

    19 Pages

  15. A WIDE RANGE

    60 Pages

  16. CRE GRUNDFOS

    2 Pages

  17. MTA

    3 Pages

  18. Unilift CC

    2 Pages

  19. ALPHA1

    2 Pages

  20. AMD-AMG-AFG

    3 Pages

  21. HS

    5 Pages

  22. SQ

    3 Pages

  23. MAGNA/UPE

    12 Pages

  24. Selcoperm SES

    20 Pages

  25. Conex DIS-C

    2 Pages

  26. Sololift2

    9 Pages

  27. VGA and VGB

    28 Pages

  28. Oxiperm Pro

    8 Pages

  29. DMX

    18 Pages

  30. DMH

    18 Pages

  31. MP 204

    3 Pages

  32. TP/TPE

    5 Pages

  33. SP Product

    7 Pages

  34. S-Tube

    4 Pages

  35. SB & SBA

    8 Pages

  36. Multilift

    21 Pages

  37. KPL and KWM

    3 Pages

  38. Grundfos GO

    3 Pages

  39. DW

    12 Pages

  40. DIP

    16 Pages

  41. NEW ALPHA2

    7 Pages

  42. GRUNDFOS DWK

    3 Pages

  43. GRUNDFOS DP

    5 Pages

  44. DME, DMS, DDI

    14 Pages

  45. Diffuser

    3 Pages

  46. CR monitor

    8 Pages

  47. Control MPC

    4 Pages

  48. CMV

    8 Pages

  49. CIM / CIU

    3 Pages

  50. BMP

    9 Pages

Archived catalogs