See other catalogues for
Grinnell
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | |
| | | |
| | | Couplings, Fittings & Flanges, End Cap with ISO R7 - Threaded Outlet | | |
| | | |
| | | FIG. 361/362 | | |
| | | |
| | | | | | | | | | | | | | | Tyco BSP Article Number | Nominal Size | Pipe OD | EtoE | C | Outlet size | Approx. Weight | | | | | mm Inches | mm | mm | mm | ISO R7 | Kg | | | | 361M00060* | 50 2 | 60.3 | 25 | 0 | DN40 (1 1/2") | 0.2 | | | | 361M00076* | 65 2 1/2 | 76.1 | 25 | 9 | DN40 (1 1/2") | 0.4 | | | | 361M00089* | 80 3 | 88.9 | 25 | 15 | DN40 (1 1/2") | 0.5 | | | | 361M00114* | 100 4 | 114.3 | 25 | 28 | DN40 (1 1/2") | 1.3 | | | | 361M00139* | 125 5 | 139.7 | 25 | 40 | DN40 (1 1/2") | 1.8 | | | | 361M00141* | 125 5 | 141.3 | 25 | 41 | DN40 (1 1/2") | 1.8 | | | | 361M00165* | 150 6 | 165.1 | 25 | 53 | DN40 (1 1/2") | 2.7 | | | | 361M00168* | 150 6 | 168.3 | 25 | 54 | DN40 (1 1/2") | 2.7 | | | | 361M00219* | 200 8 | 219.1 | 31 | 79 | DN40 (1 1/2") | 5.0 | | | | 361M00273* | 250 10 | 273.0 | 31 | 90 | DN40 (1 1/2") | 7.2 | | | | | | | | Tyco BSP Article Number | Nominal Size | Pipe OD | EtoE | C | Outlet size | Approx. Weight | | | | | mm Inches | mm | mm | mm | ISO R7 | Kg | | | | 362M00076* | 65 2 1/2 | 76.1 | 25 | 3 | DN50 (2") | 0.4 | | | | 362M00089* | 80 3 | 88.9 | 25 | 9 | DN50 (2") | 0.5 | | | | 362M00114* | 100 4 | 114.3 | 25 | 22 | DN50 (2") | 1.3 | | | | 362M00139* | 125 5 | 139.7 | 25 | 34 | DN50 (2") | 1.8 | | | | 362M00141* | 125 5 | 141.3 | 25 | 34 | DN50 (2") | 1.8 | | | | 362M00165* | 150 6 | 165.1 | 25 | 47 | DN50 (2") | 2.7 | | | | 362M00168* | 150 6 | 168.3 | 25 | 48 | DN50 (2") | 2.7 | | | | 362M00219* | 200 8 | 219.1 | 31 | 73 | DN50 (2") | 5.0 | | | | | | | | | | | | | | |
| | | |
| | | 362M00273* 273.0 31 90 DN50 (2") 7.2 * = 1 for painted RAL3000 finish, 2 for hot dipped galvanized finish General notes: Additional information is included in our data sheets and is available upon request. It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation constructions. Never remove any piping components nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified with the gasket recommendation listing for the specific application. | | |
| | | |
| | | | | |
| | | | | |
| | | |
| | | |
| | | | | | | | | | | | | | | |