Couplings, Fittings & Flanges, Lightweight Rigid
Tyco BSP Nominal Pipe Max.Wk Max.
Article Size OD Pressure t End
Number Load t mm Bar
Inches mm Psi kN
Range of Coupling Coupling Approx
Pipe End Dimensions Bolts Weight
Separation t ABC Qnt Size
mm mm mm mm mm mm Kg
577ME0034*
25
1
33.7
20.7 300
1.81
0-1.5
59
95
42
2
M10x57
0.5
577ME0042*
32
1 1/4
42.4
20.7 300
2.89
0-1.5
68
107
42
2
M10x57
0.6
577ME0048*
40 1 1/2
48.3
20.7 300
3.78
0-1.5
74
113
42
2
M10x57
0.7
577ME0060*
50 2
60.3
20.7 300
5.91
0-1.5
86
127
43
2
M10x57
0.8
577ME0073*
65
2 1/2
73.0
20.7 300
8.66
0-1.5
99
138
45
2
M10x57
0.9
577ME0076*
65
2 1/2
76.1
20.7 300
9.41
0-1 5
101
142
45
2
M10x57
0.9
577ME0089*
80
3
88.9
20.7 300
12.84
0-1.5
114
156
45
2
M10x57
1.5
577ME0114*
100 4
114.3
20.7 300
21.22
0-4.8
145
191
47
2
M10x57
1.5
577ME0139*
125 5
139.7
20.7 300
31.70
0-4.8
173
222
49
2
M12x76
2.4
577ME0141*
125 5
141.3
20.7 300
32.44
0-4.8
174
224
49
2
M12x76
2.4
577ME0165*
150 6
165.1
20.7 300
44.28
0-4.8
198
248
49
2
M12x76
2.6
577ME0168*
150 6
168.3
20.7 300
46.00
0-4.8
201
251
49
2
M12x76
2.7
577ME0219*
200 8
219.1
20.7 300
77.97
0-4.8
260
325
61
2
M16x83
5.3
* = 1 for painted RAL3000 finish, 2 for hot dipped galvanized finish
Note: The Fig. 577 Lightweight Rigid Coupling does not provide compensation for pipe system expansion and/or contraction associat­ed with pipe system temperature changes.
u
o rz
□ 0 sz
1
ACS WRAS ARPA
577MD0***2 couplings for potable water
c
c
0
577MTO***2 couplings with EPDM tri-Seal gasket for dry pipe sprinkler installations
CT
ce
-C
O
-C
<u .e
General notes: Additional information is included in our data sheets and is available upon request. It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation constructions. Never remove any piping components nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified with the gasket recommendation listing for the specific application.
D
V D
t: Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on pipe materials and/or wall thickness. Contact Tyco BSP for details. For fire protection equipment listing and approval pressure ratings contactTyco BSP
t: Maximum pipe end separation is for cut grooved standard weight pipe. Values for roll grooved will be 1/2 that of cut grooved.