1. Catalogs
  2. Pulsar Measurement
  3. PSL 5.0 Hybrid Pump Station Level Controller

PSL 5.0 Hybrid Pump Station Level Controller

PSL 5.0 Hybrid Pump Station Level Controller

PSL 5.0 Hybrid Pump Station Level Controller

Product catalog summary
Overview: The Greyline PSL 5.0 is an automatic, hybrid pump station level controller designed for level control in pump stations, wet wells, and tanks. It features a non-contacting ultrasonic sensor and offers six programmable control relays for various functions including pump control and level alarms.
Key Features:
  • No Contact, No Maintenance: The ultrasonic sensor is mounted in the tank or wet well, with electronics installed up to 152.4 m away. It includes a simple menu system for setup.
  • Dual-Technology Sensor: Offers redundant level sensing with a submersible pressure sensor or another 4-20mA level transmitter for fail-safe operation.
  • Easy Installation: The non-contacting sensor mounts above the well or tank, with easy calibration via a built-in keypad.
  • Relay Run Time Reporting: Provides a relay run time report to identify pump performance and plan maintenance.
Technical Specifications:
  • Accuracy: ±0.25% of range or 2 mm.
  • Operating Temperature: -20 °C to +60 °C for electronics.
  • Power Input: 100-240 V AC, 50-60 Hz.
  • Control Relays: Six form ‘C’ dry contact relays, rated 5 A SPDT.
  • Display: White, backlit matrix for calibration menu and status.
Transducer Specifications:
  • Standard Sensor: PZ34 ultrasonic sensor with a maximum range of 9.8 m.
  • Operating Frequency: 42 kHz.
  • Operating Temperature: -40 °C to 65 °C.
Popular Options:
  • Long and short-range sensors, intrinsically safe options, and pressure sensors.
  • Data logger with 20 million point capacity and USB output.
  • Enclosure heater for temperatures below 0 °C.
Applications: Ideal for water, wastewater, and process automation, the PSL 5.0 is designed for harsh conditions in wet well or tank level control applications.
See more

Catalog excerpts

PSL 5.0 Hybrid Pump Station Level Controller-1

Automatic, hybrid pump station level controller with a non-contacting, ultrasonic sensor. Pump Station Level Control, Monitoring & Reporting Ideal for Level Control Designed for pump stations, wet wells, and tank level control – the Greyline PSL 5.0 Pump Station Level Controller has six independently programmable control relays for pump or valve control, level alarms, autodialers, temperature, or fault alarms. THE RIGHT METER FOR • Pump Stations • Tank Level Control Mount the non-contacting, ultrasonic sensor in the tank or wet well and install the watertight electronics in the control room or any location within 152.4 m (500 ft). Use the simple menu system and built-in keypad to set up measurement range, relay set points, and pump alternation sequence. A relay/pump run time report is updated and stored automatically for viewing on the instrument’s backlit LCD display. Dual-Technology Sensor Feature: Redundant Level Sensing Connect a submersible pressure sensor or another 4-20mA level transmitter to the PSL 5.0 for failsafe hybrid sensing. The PSL 5.0 will auto-calibrate the redundant sensor and if the signal is lost to the ultrasonic sensor, the redundant sensor will seamlessly I N F O @ P U L S A R M E A S U R E M E N T . C O M take over monitoring until the signal resumes from the ultrasonic. The redundant sensor is continuously monitored to ensure availability during primary sensor failure. Easy to Install with NonContacting Sensor The Greyline PSL 5.0 Pump Station Level Controller is designed for pump station and tank level control applications with the noncontacting sensors mounting just above the well or at the top of a tank. Calibration is simple and easy, use the built-in keypad to calibrate

 Open the catalog to page 1
PSL 5.0 Hybrid Pump Station Level Controller-2

measurement span, relay set points, pump alternation sequence, and level alarms. Assign the six built-in control relays for ON / OFF pump control, high- or low-level alarms, autodialer activation, air temperature alarm, or sensor echo loss alarm. Connect the isolated 4-20mA output to your SCADA system, PLC’s, or recorders, for easy integration with existing plant control systems. Redundant Sensor Level Control Non-contacting, ultrasonic sensor The PSL 5.0 sets a new level of reliability. It operates with an ultrasonic level transducer as its primary sensor but also accepts connections from 4-20mA...

 Open the catalog to page 2
PSL 5.0 Hybrid Pump Station Level Controller-3

Technical Specifications GENERAL SPECIFICATIONS ±0.25% of Range or 2 mm (0.08 in), whichever is greater Operating Temp. (Electronics): Analog Output: Electronics Enclosure: NEMA4X (IP66) polycarbonate with clear, shatterproof cover Power Input: 100-240 V AC 50-60 Hz (see Options), 2.4-5.6 W depending on options Control Relays: 6 form ‘C’ dry contact Relays rated 5 A SPDT; programmable level alarm and/or pump control modes, pump alternation / sequencing, failsafe / echo-loss, air temperature alarm White, backlit matrix - displays calibration menu, relay status, runtime reports and sensor status...

 Open the catalog to page 3
PSL 5.0 Hybrid Pump Station Level Controller-4

Reliable, Accurate, Simple Calibration: • Built-in, 5-button keypad • Easy calibration with 6 control relays for simplex pump stations, duplex, triplex, quadruplex, or more... • Non-Contacting, no-maintenance, ultrasonic sensor • Redundant level sensor connection – use any 4-20mA transmitter for failsafe level sensing • Independently programmable Pump Up and Pump Down modes • Programmable “forced alternation” to prevent pump damage • Isolated 4-20mA output for connection to Variable Speed Drives, SCADA systems, PLC’s, or Recorders • Plug and Play options including a 20 million point data logger...

 Open the catalog to page 4

All Pulsar Measurement catalogs and technical brochures

  1. MICROFLOW

    2  Pages

  2. FLOW PULSE

    2  Pages

  3. Radar Sensors

    4  Pages

  4. Model DFM 6.1

    4  Pages

  5. AVFM 6.1

    4  Pages

  6. TTFM 6.1

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.