You may also be interested in
EF Series
300-400 Watt High Density AC/DC Power Supply P
RODUCT
D
ESCRIPTION
The EF Series of switching
power supplies utilizes advanced component and circuit technologies to deliver the industry’s smallest 350-400 Watt switcher. Built to meet 1U height considerations, the U-Frame package measures only 6.80 x 3.86 x 1.40”. All models offer universal AC input (85-265 VAC) with active power factor correction (PFC), optional 48 VDC input, flexible output configurations and compliance to worldwide safety and EMC standards. Features include:• 350W & 400W compact high-density models• Active load current share
• Universal AC input with PFC
• Ruggedized U-Channel construction
• 48V & 24V DC Input models available
• RoHS compliant
• Includes OR-ing diode for N+1 parallel operation
• International regulatory approvals
I
NPUT
S
TATUS
& C
ONTROL
AC Input Voltage
90-264VAC, 47-63Hz
Remote Inhibit
ACTIVE Low-output shut down
Input Inrush Current
Power OK
Open Collector ACTIVE Low - Any Output drops below 10%
Power Factor Correction
>0.98 Typical @ 110/220VAC input @ Full Load
Current Share
Single Wire, ±10% accuracy
Input Line Protection
6.3A 250VAC IEC Type
Remote Sense
Compensates for Hold-up Time
16mSec.@ Full Load
Auxillary Output
5V / 5mA
O
UTPUT
E
LECTROMAGNETIC
C
OMPATIBILITY
Line Regulation
± 0.1% for Vin (min.) to Vin (max.)
Electrostatic Discharge
EN61000-4-2, ±4KV Contact / ±8KV Air Discharge
Transient Response
Better than 5% For 50% Step Load
Radiated Susceptibility
EN61000-4-3, 26-1000MHz, 10V/M, 80% AM
Over-Voltage Protection
120% Typical Latched Shut-down
EFT / Bursts
EN61000-4-4, ±2KV
Load Regulation
± 1% Max
Surges
EN61000-4-5, ±2KV Line-Earth, ±1KV Line-Line
Min. Load Requirement
None
Conducted Immunity
EN61000-4-6, 0.15-800MHz, 10V, 80% AM
Turn-On Delay
2 Sec. Max.
Voltage Dips
EN61000-4-11, 95% Dip & 10ms, 30% Dip & 500ms
Initial Setting Accuracy
± 1%
Voltage Interruptions
EN61000-4-11, 95% Reduction, 5s
Ripple @ Noise
± 1%
Fluctuations & Flicker
EN61000-3-3
Overload Protection
125% Typical of Max Output Load
E
NVIRONMENTAL
S
AFETY
& E
MISSIONS
Operation Temperature
-5C to +50C. De-rate of 2.5% per 1Deg. C up to +71C
Safety Approvals
EN-60950’ c/UL60950 & CE Marking
Temperature Protection
Shutdown (Internal Heat-Sink Temp. >90C ), Auto recovery
Storage Temperature
-25C to +85C
Cooling
Forced Air Cooling 15CFM
Humidity
Up to 95% RH Non-condensing
Shock & Vibration
0.75G Peak 5Hz - 500Hz
MTBF
>300,000 Hours Phone: (866) 344-7697www.digipwr.comDigital Power Corporation