You may also be interested in
Magnetic pump, Diaphragm pump, Bellow pump, Piston pump, Centrifugal pump
Text version of the page
©2009 Gorman-Rupp Industries BleachCompatibleMiniBellowsPumpSelect
180 Hines Ave. Bellville, OH 44813 PH: 419-886-3001 FAX: 419-886-2338 www.GRIpumps.com GRIsales@GRIpumps.com
Pump Selection BLEACH COMPATIBLE
MINI BELLOWS PUMPS
Bleach Compatible Mini Bellows Pumps Selection Overview
Select a bellows size that meets your pressure requirements. Select a model with the bellows size that provides your required flow while operating
closest to full stroke capacity. Best metering accuracy occurs when bellows modules operate at 50% or more of maximum output. For 24 hour
continuous duty service, use one of the heavy-duty models.
Select connectors for each bellows from the selection charts at the end of this section. (Please consult factory for Bleach Compatible duckbill requirements).
Order Notes: When ordering a Bleach Compatible mini bellows model, refer to steps 1 and 2 and follow the example provided.
Example: The model number and code for a single pump with 1 bellows module and 38 barbed connector and driven by a 115V, 8 RPM, 50/60
Hz, motor would be: 16200-403 T-103.
1. Using Chart A and B, select bellows
module(s) and a motor RPM combination
whose maximum output meets or
exceeds your flow requirements. Best
metering accuracy occurs when bellows
modules operate at 50% or more of their
maximum output. Then refer to Chart E to
select an appropriate model number.
2. Using Tubing Connector Chart G, select
one T-code.
Charts continued on next page
BELLOWS MODULE OUTPUT
Bellows Size 1/2 3/4 1 11/2 2
Full Stroke
Displacement (ml) .5 1.8 5 10.5 18
CHART A
MAXIMUM FLOW/ MAXIMUM PRESSURE - SINGLE PUMPS
Max Flow
(ml/min)
Bellows Size
1/2 3/4 1 11/2 2
Motor RPM 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
8 3.3 4.0 12.0 14.4 33.3 40.0 70.0 84.0 120.0 144.0
15 6.2 7.5 22.5 27.0 62.5 75.0 131.3 157.5 225.0 270.0
24 10.0 12.0 36.0 43.2 100.0 120.0 210.0 252.0
CHART B
|
|