3-348-858-03 7/3.06 GMC-I Gossen-Metrawatt GmbH METRISO®5000 A/AK High-Voltage Insulation Tester DQS certified per DIN EN ISO 9001 Reg. No.1262 QUALITY MANAGEMENT SYSTEM Features Test Voltages to 5000 V This instrument is suited for the non-destructive measurement of insulation resistance in electrical systems, at machines and transformers and in cables, as well as within the electrical equipment of, for example, locomotives, tram systems and ocean going vessels, with eight selectable test voltages up to 5 kV. Voltage Measurement to 2000 V With the voltage measuring ranges, test objects can be checked for the absence of voltage in networks of up to 2 kV. This is important for insulation resistance measurement, because extraneous voltages distort measurement results. Discharge of Capacitive Devices Under Test Capacitive devices under test such as cables and coils, which might be discharged to test voltage, are discharged by the measuring instrument. The drop in voltage can be observed at the needle gauge. Measurements in accordance with EN 61557 part 1 and 2 (VDE 0413) Measuring current is equal to 1 mA at a test voltage of 100 V, 250 V, 500 V and 1000 V. Measurement Cables with Heavy-Duty Insulation The measurement cables with heavy-duty insulation are permanently connected for safety and technical reasons. Possible danger caused by the unintentional removal of cables is thus avoided, for example when charging occurs due to capacitive test objects. Needle Gauge with LEDs Three LEDs arranged within the needle gauge make reading easier. The lamp lights up which is located next to the scale, which is assigned to the selected measuring range. During the measurement sequence, the green LED indicates whether or not the battery charge is sufficient for the measurement. Applicable Regulations and Standards IEC 61010-1 EN 61010-1 VDE 0411-1 Safety regulations for electrical measurement, control, regulation and lab devices – General requirements DIN VDE 0413 part 1 Devices for the testing of safety requirements for electrical systems – Insulation measuring devices IEC 61557 EN 61557 VDE 0413 Part 1 Part 2 Measuring and monitoring facilities for testing the electrical safety in lines with nominal voltages up to AC 1000 V and DC 1500 V – General – Insulation resistance measuring devices IEC/EN 61326-1 Generic Emission Standard; Electrical equipment for measurement, control and laboratory use IEC/EN 61326 VDE 0843 part 20 Electrical equipment for measurement, control and laboratory use – EMC requirements DIN EN 60529 DIN VDE 0470 part 1 Test instruments and test procedures – degree of protection provided by enclosures (IP code) • Broad measuring range from 10 kŮ to 1 TŮ • Easy to read logarithmic display • Test voltages: 100 V, 250 V, 500 V, 1000 V, 1500 V, 2000 V, 2500 V, 5000 V • Measurement to 2000 V in accordance with DIN VDE 0413 • Measuring range: 100 kŮ to 100 MŮ (1000 V) • Voltage measurement to 2000 V , • Guard terminal eliminates surface current • 5 m extension cable as accessory equipment • Power supply with batteries or hand crank generator (optional) Applications Insulation measurement for cables, motors etc.

pageCatalog pdf di En 2012-05-19-09