3-349-304-03 2/7.04 GOSSEN METRAWATT GMBH METRA HIT 1A and METRA HIT 2A Analog Multimeters 500 V CAT II IEC/EN 61010-1, Second Edition 5 Ampere 15 Ampere / Class 2.5 Broad Range of Applications A large number of measuring ranges allows for universal use of the instruments, for example in electronics, digital technology and a wide variety of general electrical applications. Safety Features The connector jacks and plugs included with the measurement cables which are available as accessories are protected against inadvertent contact. Measuring Range Selector Switch All measuring ranges are selected with a rotary switch. Rugged Mechanical Design The rugged plastic housing and the spring loaded bearing jewels in the moving-coil mechanism protect the instrument from damage due to mechanical stressing. Especially effective protection is provided by the protective rubber cover and the ever-ready case, both of which are available as accessories. Applicable Regulations and Standards Characteristic Values Voltage Measuring Ranges 1) 0 dB 0.775 V in the 1.5 V range, 0 dB 1 mW to 600 Ů Voltage related input resistance: for : 20.0 kŮ/V for : 4.0 kŮ/V METRA HIT 1A: Current Measuring Ranges IEC/EN 61010-1:2001/ VDE 0411-1:2002 Safety requirements for electrical equipment for measurement, control and laboratory use EN 60529 VDE 0470, part 1 Test instruments and test procedures, degrees of protection provided by enclosures (IP code) DIN EN 61326 VDE 0843, part 20 Electrical equipment for control technology and laboratory use – EMC requirements Voltage Output 1) Internal Resistance, Approx. 0.15 V — 3.15 kŮ — 0.50 V — 10.00 kŮ — 1.50 V -15 ... + 6 dB 31.50 kŮ 6.50 kŮ 5.00 V - 5 ... + 16 dB 100.00 kŮ 20.00 kŮ 15.00 V + 5 ... + 26 dB 315.00 kŮ 65.00 kŮ 50.00 V +15 ... + 36 dB 1.00 MŮ 200.00 kŮ 150.00 V +25 ... + 46 dB 3.15 MŮ 650.00 kŮ 500.00 V +35 ... + 56 dB 10.00 MŮ 2.00 MŮ Current Voltage Drop, Approx. 50.00 ěA 0.158 V — 0.50 mA 1.15 V 1.00 V 5.00 mA 1.25 V 1.25 V 50.00 mA 1.25 V 1.25 V 500.00 mA 1.85 V 1.85 V 5000.00 mA 1.73 V 1.73 V • Voltage measurement: 0...0.15, 0...0.5 V=, 0 ...1.5, 5, 15, 50, 150, 500 V=/~ • Input resistance: 20 kŮ/V=, 4 kŮ/V~ • Current measurement: 0 ... 50 ěA=, 0 ... 0.5, 5, 50, 500 mA, 5 A=/~ • Extended current measurement, METRA HIT 2A: ... 15 A=/~ • Resistance measurement: 1 Ů ... 1 MŮ (4 ranges) • Capacitance: 200 mF ... 2 ěF (4 ranges) • Level: -15 ... +56 dB (6 ranges)

pageCatalog pdf di En 2012-05-22-29