Models D1010S-046, D1010D-046 - 1

SIL 2 Repeater Power Supply Smart-Hart compatible DIN-Rail Models D1010S-046, D1010D-046 1 2 3 000C Characteristics: General Description: The single and dual channel DIN Rail Repeater Power Supply, D1010S-046 and D1010D-046, provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA transmitters, or separately powered 3, 4 wires 4-20, 0-20 mA transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional communication signals, for Hart-Smart transmitters. Function: 1 or 2 channels I.S. analog input for 2 wires loop powered or separately powered Smart transmitters, provides 3 port isolation (input/output/supply) and current (source or sink) or voltage output signal. Signalling LED: Power supply indication (green). Field Configurability: mA (source or sink) or V output signal. Smart Communication Frequency Band: 0.5 to 40 KHz within 3 dB (Hart and higher frequency protocols). EMC: Fully compliant with CE marking applicable requirements. Functional Safety Management Certification: G.M. International is certified by TUV to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. • SIL 2 according to IEC 61508:2010 Ed. 2 for Tproof = 7 / 10 years (s10% / >10 % of total SIF) with active input. • SIL 2 according to IEC 61508:2010 Ed. 2 for Tproof = 6 / 10 years (s10% / >10 % of total SIF) with passive input. • PFDavg (1 year) 1.30 E-04, SFF 80.51 % with active input. • PFDavg (1 year) 1.47 E-04, SFF 80.81 % with passive input. • SIL 3 Systematic capability. • Input from Zone 0 (Zone 20), installation in Zone 2. • 4-20 or 0-20 mA Input, Output Signal. • Wide Band Smart Communication, Hart compatible. • Input and Output short circuit proof. • High Accuracy. • Three port isolation, Input/Output/Supply. • EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1 . • In-field programmability by DIP Switch. • ATEX, IECEx, INMETRO, EAC-EX, UKR TR n. 898, TUV Certifications. • TUV Functional Safety Certification. • Type Approval Certificate DNV and KR for maritime applications. • High Reliability, SMD components. • High Density, two channels per unit. • Simplified installation using standard DIN Rail and plug-in terminal blocks. • 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. Power Bus and DIN-Rail accessories: DIN rail anchor MCHP065 DIN rail stopper MOR016 Terminal block male MOR017 Terminal block female MOR022 Technical Data: Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits s 5 Vpp. Current consumption @ 24 V: 115 mA for 2 channels D1010D-046, 60 mA for 1 channel D1010S-046 with 20 mA output typical. Power dissipation: 1.9 W for 2 channels D1010D-046, 1.0 W for 1 channel D1010S-046 with 24 V supply voltage and 20 mA output typical. Max. power consumption: at 30 V supply voltage and short circuit condition, 3.7 W for 2 channels D1010D-046, 2.0 W for 1 channel D1010S-046. Isolation (Test Voltage): I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V. Input: 0/4 to 20 mA (separately powered input, voltage drop s 1.1 V) or 4 to 20 mA (2 wire Tx current limited at = 25 mA). Transmitter line voltage: a 14.0 V at 20 mA with max. 20 mVrms ripple on 0.5 to 40 KHz frequency band. Output: 0/4 to 20 mA, on max. 600 Q load in source mode; V min. 5 V at 0 Q load V max. 30 V in sink mode, current limited at = 23 mA or 0/1 to 5 V on internal 250 Q shunt (or 0/2 to 10 V on internal 500 Q shunt on request). Response time: 50 ms (10 to 90 % step change). Output ripple: s 20 mVrms on 250 Q communication load on 0.5 to 40 KHz band. Frequency response: 0.5 to 40 KHz bidirectional within 3 dB (Hart and higher frequency protocols). Performance: Ref. Conditions 24 V supply, 250 Q load, 23 ± 1 °C ambient temperature. Calibration accuracy: s ± 0.1 % of full scale. Linearity error: s ± 0.05 % of full scale. Supply voltage influence's ± 0.05 % of full scale for a min to max supply change. Load influence: s ± 0.05 % of full scale for a 0 to 100 % load resistance change. Temperature influence: s ± 0.01 % on zero and span for a 1 °C change. Compatibility: /* £ CE mark compliant, conforms to Directive: V. Vi 2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. Environmental conditions: Operating: temperature limits -20 to + 60 °C, relative humidity max 95 %. Storage: temperature limits - 45 to + 80 °C. Safety Description: ATEX: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; II 3G Ex nA IIC T4 Gc IECEx/INMETRO: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I; Ex nA IIC T4 Gc EAC-EX: 2Ex nA [ia Ga] IIC T4 Gc X, [Ex ia Da] IIIC X, [Ex ia Ma] I X UKR TR n. 898:2ExnAiaIICT4 X, ExiaI X associated apparatus and non-sparking electrical equipment. Uo/Voc = 26.3 V, Io/Isc = 79 mA, Po/Po = 514 mW at terminals 14-15, 10-11. Uo/Voc = 1.1 V, Io/Isc = 28 mA, Po/Po = 8 mW at terminals 15-16, 11-12. Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1.05 nF, Li = 0 nH at terminals 15-16, 11-12. Um = 250 Vrms, -20 °C s Ta s 60 °C. Approvals: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26. IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26. IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-15. IECEx IMQ 13.0011X conforms to IEC60079-0, IEC60079-15. INMETRO DNV 13.0108 X conforms to ABNT NBR IEC60079-0, ABNT NBR IEC60079-11, ABNT NBR IEC60079-15, ABNT NBR IEC60079-26, ABNT NBR IEC 61241-11. C-IT.MH04.B.00306 conforms to GOST R IEC 60079-0,GOST R IEC 60079-11, GOST R IEC 60079-15. CM 16.0034 X conforms to flCTy 7113, rOCT 22782.5-78, flCTy IEC 60079-15. TUV Certificate No. C-IS-236198-03, SIL 2 conforms to IEC61508:2010 Ed.2. TUV Certificate No. C-IS-236198-09, SIL 3 Functional Safety Certificate conforms to IEC61508:2010 Ed.2, for Management of Functional Safety. DNV No.A-13778 and KR No.MIL20769-EL001 Certificates for maritime applications. Mounting: T35 DIN Rail according to EN50022. Weight: about 175 g D1010D-046, 125 g D1010S-046. Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2. Location: Safe Area or Zone 2, Group IIC T4 installation. Protection class: IP 20. Dimensions: Width 22.5 mm, Depth 99 mm, Height 114.5 mm.

Open the catalog to page 1

All GM International srl catalogs and technical brochures

  1. D5030

    1 Pages

  2. D1020

    2 Pages

  3. D5020

    1 Pages

  4. Model 5700

    4 Pages