Model 5700
4Pages

{{requestButtons}}

Catalog excerpts

Model 5700 - 1

Technical Data: General Description: The HART® Multiplexer Modem 5700 interfaces up to 256 smart devices (transmitters, I/P, proportional valves, etc…) in a HART® Network. Each device can be fully identified, configured and monitored by a remote PC running an FDT-based software package (PACTware™, etc...) through a dedicated Device Type Manager (DTM). Up to 63 Multiplexer Modem 5700 (16128 loops) can be connected in multi-drop mode to the PC through the RS485 HART® Protocol, whose baudrate can be configured via software. The module is intended to be mounted on the following Termination Boards:  TB-D5001-HRT-003: to be used with G.M. International AI/AO Termination Boards;  TB-D5001-HRT-004: to be used with DIN-Rail mounted barriers/isolators or direct field connections, for 4-20mA loop signal;  TB-D5001-HRT-005: to be used with DIN-Rail mounted barriers/isolators or direct field connections, for 1-5V loop signal. Termination board types can be combined to manage different interfaces at the same time, simply respecting maximum number of connected channels. The HART® Multiplexer Modem 5700 is SIL 3 certified as non-interfering with the signal loops. The module guarantees three-port (supply/interface/channels) isolation. Functional Safety Management Certification: G.M. International is certified by TUV to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. Front Panel and Features: SIL 3 according to IEC 61508:2010 Ed. 2. Systematic capability SIL 3. Input from Zone 2, installation in Zone 2. High Density, 256 Input channels. CONFIG SIL 3 HART® Multiplexer Modem suitable for Termination Board, Model 5700 HART® field device input, revision 5 to 7. Supply: 24 Vdc nom (18 to 30 Vdc) reverse polarity protected, via Termination Board. Current consumption @ 24 V: 40 mA (in full topology configuration) typical. Power dissipation: 0.5 W @ 24 V typical (modem only), 1 W @ 24 V typical (in full topology configuration). Isolation (Test Voltage): Interface/Power Supply: 500 Vrms. Interface/Field channels: 500 Vrms. Power Supply/ Field channels: 500 Vrms. Input: Number of channels: 256. HART® field device Input: revision 5 to 7. Interface: Baudrate: from 1200 to 115200 bps, software configurable. Address: 0 - 62, software configurable. Type: RS-485 differential pair and grounding. Topology: multi-drop, master/slave connection. Compatibility: CE mark compliant, conforms to Directives: 2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. Environmental conditions: Operating: temperature limits – 40 to + 70 °C, relative humidity 95 %, up to 55 °C. Storage: temperature limits – 45 to + 80 °C. Safety Description: ATEX: II 3G Ex nA IIC T4 Gc IECEx: II 3G Ex nA IIC T4 Gc non-sparking electrical equipment. Approvals: ATEX conforms to EN60079-0, EN60079-15 (pending). IECEx conforms to IEC60079-0, IEC60079-15 (pending). SIL 3 conforms to IEC61508:2010 Ed. 2 (pending). TÜV Certificate No. C-IS-236198-09, SIL 3 Functional Safety Certificate conforms to IEC61508:2010 Ed.2, for Management of Functional Safety. Mounting: on customized Termination Board. Weight: about 100 g. Location: installation in Safe Area or Zone 2, Group IIC T4. Protection class: IP 20. Dimensions: Width 12.5 mm, Depth 123 mm, Height 120 mm. Three port isolation, Supply/Interface/Channels. POWER COMM. OPER. EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1 for safety system. ATEX, IECEx, TÜV Certifications (pending). TÜV Functional Safety Certification. Simplified installation using standard customized Termination Boards. RS-485 Interface. Ordering Informat

Open the catalog to page 1
Model 5700 - 2

Function Diagram: SAFE AREA, ZONE 2 GROUP IIC T4 = = optional write protection Serial interface HART Modem Termination board connector

Open the catalog to page 2
Model 5700 - 3

Loop Diagrams (IS Applications): HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC 1) Barriers on Termination Boards Process control system e.g. DCS,PLC SAFE AREA, ZONE 2 GROUP IIC T4 Workstation PC running instrument management software up to 16128 HART® devices HART® transmitters and valve positioners DIN-Rail AI/AO BaTiers HART® transmitters and valve positioners DIN-Rail AI/AO Barriers Process control system e.g. DCS,PLC -HRT-xxx -HRT-xxx -HRT-xxx xxx > 004 RS485 HART® _ 4/20 mA or 1-5 V _ HART® _ 4/20 mA + HART®

Open the catalog to page 3
Model 5700 - 4

Loop Diagrams (Non-IS Applications): SAFE AREA, ZONE 2 GROUP IIC T4 1) Isolators on Termination Boards Workstation PC running instrument management software up to 16128 HART® devices Process control system e.g. DCS,PLC RS232/RS485 converter Up to 63 HART® Mux 5700 modules 4/20 mA signals HART® transmitters and valve positioners GMI TB 1 2) Isolators on DIN-Rail or Direct Field Connections RS232/RS485 converter AI/AO Isolators Workstation PC running instrument management software up to 16128 HART® devices Process control system e.g. DCS,PLC transmitters and valve positioners HART® 4/20 mA...

Open the catalog to page 4

All GM International srl catalogs and technical brochures

  1. D5030

    1 Pages

  2. D1020

    2 Pages

  3. D5020

    1 Pages