GLOBE vane air motors - Globe - #19

/ 20


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
Pages:


See other catalogues for Globe

Text version of the page

PERFORMANCE V10

12.8 HP/9.5 kW REVERSIBLE

GRAPH 1 TORQUE - SPEED SPEED revs per min GRAPH 2 STARTING TORQUE - PRESSURE PRESSURE P.S.I.
100 45403020100
123456 90 PSI 80 6 Bar 4535205
70 60 PSI 4 Bar 50 40 MAXIMUM STARTING TORQUE 12
30 PSI 2 Bar TORQUE Nm TORQUE (lbs ft.) MINIMUM STARTING TORQUE 153040
TORQUE Nm TORQUE (lbs ft.) 10 268101416182224262830323436352515520 0420 0 20060080010001200140016001800200022002400 400 00102030405060708090100 3040PRESSURE bar 0102550 GRAPH 3 POWER - SPEED GRAPH 4 CONSUMPTION - SPEED SPEED revs per min 9 150 320340 0 1401109070400 8
6 Bar 6 Bar 100 12060 7430 260280
90 PSI 80 4 Bar 100 6 1 220
70 200
90 PSI 4 Bar 60 PSI 80 5
50 70 40 2 Bar 140160
HORSE POWER 60 PSI 50 POWER kW 120
30 PSI 40 2 Bar litres/sec. free air AIR CONSUMPTION cu. ft/min. free air 34710121311
30 PSI 2 80 25689 60100180240300 20305080100130 10 2040 10 200400600800 10001200140016001800200022002400 200400600800 10001200140016001800200022002400 SPEED revs per min

Attitude: Polar Moment of Inertia:

The motor can be operated in all positions. 30 lb.in2 (8.8 g.m2).

Airline filtration and lubrication: Maximum overhung force on shaft:

Use 64 micron filtration or better. Choose a lubricatorsuitable for the flow required. Prior to start up, inject oil into the inlet port. 400 lbf (1750N) In certain circumstances this may be extended. Consult your Globe Distributor. Axial loads should be kept down to a minimum.

Lubricator drop rate: Maximum temperatures:

8-10 drops per minute continuous operation. 14-16 drops per minute intermittent operation. -40°to +176°Farenheit. (-20°to +80°C )

19