PERFORMANCE V6
4.6 PEAK HP/3.4 kW REVERSIBLE
GRAPH 1 TORQUE - SPEED
SPEED revs per min GRAPH 2 STARTING TORQUE - PRESSURE
PRESSURE P.S.I. 1412106420 >
10090 PSI 123456 15 >
80 6 Bar4 Bar2 Bar 13 >
70 121197431 >
60 PSI 8 >
50 8 >
40 30 PSI TORQUE Nm TORQUE Nm TORQUE (lbs ft.) TORQUE (lbs ft.) MAXIMUM STARTING TORQUE MINIMUM STARTING TORQUE 481418 0246810
050010001500200025003000 00102030405060708090100256101416PRESSURE bar 02610121620 GRAPH 3 POWER - SPEED GRAPH 4 CONSUMPTION - SPEED
SPEED revs per min 543210050010001500200025003000 70 6555403020100 3210 >
6 Bar 6 Bar 100 100 90 PSI 90 PSI 4 Bar 45 >
80 80 70 70 4 Bar 60 PSI HORSE POWER POWER kW 50 2 Bar 60 PSI 40 50 40 30 PSI litres/sec. free air
AIR CONSUMPTION cu. ft/min. free air 2 Bar 30 PSI 1030405060
7080
90100110120130140150160 51525355060 020050010001500200025003000 SPEED revs per min >
Attitude: Polar Moment of Inertia:
The motor can be operated in all positions. 1.56 lb.ins2 (0.45 g.m2).
Airline filtration and lubrication: Maximum overhung force on shaft:
Use 64 micron filtration or better. Choose a lubricatorsuitable for the flow required. Prior to start up, inject oil
into the inlet port. 70 lbf (300N) In certain circumstances this may be extended.
Consult your Globe Distributor. Axial loads should be kept
down to a minimum.
Lubricator drop rate: Maximum temperatures:
5-6 drops per minute continuous operation.
10-12 drops per minute intermittent operation. -4°to +176°Farenheit. (-20°to +80°C )
15