| | | | | | | | | | | | | | | | | | | Phoenix Technical data Electrical characteristics | | | | | | | | | | | | | | | | | | | | | | | | EN 60947-3 CHARACTERISTICS | | | PO12 | PO16 | PO20 | CO25 | CO32 | CO40 | | | | Rated operating voltage Ue | | V | 690 | 690 | 690 | 690 | 690 | 690 | | | | Rated insulation voltage Ui | | V | 690 | 690 | 690 | 690 | 690 | 690 | | | | Rated impulse voltage Uimp | | kV | 4 | 4 | 4 | 6 | 6 | 6 | | | | Rated thermal current Ith | | A | 12 | 16 | 20 | 32 | 40 | 50 | | | | Rated thermal current enclosed Ithe | | A | 12 | 16 | 20 | 25 | 32 | 40 | | | | Frequency | | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | | | | RATED OPERATING CURRENT Ie: alternate current | | | | | | | | | | | | AC-21A Switching resistive loads with light overloads | 690V | A | 12 | 16 | 20 | 25 | 32 | 40 | | | | AC-22A Switching mixed resistive and inductive loads with light overloads | 690V | A | 12 | 16 | 20 | 25 | 32 | 40 | | | | AC-23A Periodic switching Single-phase - 2-pole of motors | 110V 230V | A/kW A/kW | 12/1,1 12/2,2 | 14/1,5 14/3 | 18/2 18/4 | 20/1,5 25/4 | 25/2,2 30/5,5 | 35/3 35/6,5 | | | | | 230V | A/kW | 10/3 | 13/4 | 16/5 | 25/7,5 | 30/9 | 35/11 | | | | 3-phase - 3-pole | 400V | A/kW | 10/5,5 | 13/7,5 | 16/9 | 22/11 | 27/15 | 32/18,5 | | | | 500V | A/kW | 10/7,5 | 14/10 | 16/11 | 22/15 | 27/18,5 | 32/22 | | | | | 690V | A/kW | 10/7,5 | 14/10 | 16/12,5 | 16/15 | 20/18,5 | 25/22 | | | | AC3 Starting of cage motors Single-phase - 2-pole (interruption while running) | 110V 230V | A/kW A/kW | 10/0,75 10/2 | 12/11 12/2,2 | 16/1,5 16/3,5 | 16/1,1 20/3,7 | 20/1,5 25/4 | 30/2,5 30/5,5 | | | | | 230V | A/Kw | 8/2,2 | 10/3 | 12/4 | 18/5,5 | 23/7,5 | 27/9 | | | | 3-phase - 3-pole | 400V | A/kW | 8/4 | 10/5 | 10/6 | 16/7,5 | 20/11 | 27/15 | | | | 500V | A/kW | 8/5 | 10/7,5 | 12/8 | 16/11 | 20/15 | 27/18,5 | | | | | 690V | A/kW | 6/5,5 | 8/7,5 | 10/9 | 12/11 | 16/15 | 20/18,5 | | | | RATED OPERATING CURRENT Ie: direct current | | | | | | | | | | | | DC-21A Switching resistive loads with light 50V (Single pole) overloads (1 phase) | A | 10 | 12 | 16 | 20* | 25* | 32* | | | | DC-22A Switching mixed resistive and inductive 30V (Single pole) loads with light overloads (1 phase) | A | 8 | 10 | 12 | 16* | 20* | 25* | | | | AC-23A Periodic switching of motors (cosfi 0.45) | 230V 400V 500V 690V | A A A A | 128 128 128 128 | 128 128 128 128 | 128 128 128 128 | 280 256 256 200 | 280 256 256 200 | 280 256 256 200 | | | | Power dissipation for each phase | | W | 0,3* | 0,35* | 0,4* | - | - | - | | | | SHORT CIRCUIT CHARACTERISTICS | | | | | | | | | | | | Rated short-time short circuit withstand current Icw (1s) | | A | 300 | 300 | 300 | 500 | 500 | 500 | | | | Rated short circuit making capacity Icm | | A | 1200 | 1200 | 1200 | 2840 | 2840 | 2840 | | | | Conditional rated short circuit withstand current | | kA | 5 | 5 | 5 | 10 | 10 | 10 | | | | Fuse rating gG | 690V | A | 20 | 20 | 20 | 40* | 400 | 40 * | | | | UL 508 CHARACTERISTICS | | | | | | | | | | | | General Use | 600V ac | A | 12 | 16 | 20 | 25 | 32 | 40 | | | | Standard motors load | 120V ac | HP(FLA) | 0,5 (9,8) | 1 (16) | 1,5 (20) | 1,5(20) | 2 (24) | 3 (34) | | | | Single-phase - 2-pole 3-phase - 3-pole | 240V ac 200V ac 240V ac 480V ac | HP(FLA) HP(FLA) HP(FLA) HP(FLA) | 1 (8) 1,5 (9) 3 (9,6) 5 (7,6) | 1,5 (10) 3 (14,4) 5 (15,2) 7,5 (11) | 2 (12) 5 (22,8) 5 (15,2) 10 (14) | 3 (17) 7,5 (25,3) 7,5 (22) 15 (21) | 5 (28) 7,5 (25,3) 7,5 (22) 20 (27) | 5 (28) 10 (32,2) 10 (28) 20 (27) | | | | | 600V ac | HP(FLA) | 5 (6,1) | 7,5 (9) | 10 (11) | 15 (17) | 20 (22) | 20 (22) | | | | | | | | | | | | | | | | | | | | | | | | *Values not reported on the IMQ file * Fuses gG 40A-500V | | | | | | | | | | 28 | | | | | | | | | | | | | | | | | | |
|