state of revision 02 | March 2007 up to 10 bar (145 psi)
AirLiquid PN-Module
pneumatic module >>>
fully compatible with: Amphenol C 146 M | Hypertac HYM (Hypermod) | Lapp Contact EPIC MC (Lapp Group) Thomas & Betts Pos-E-Con M | Walther Werke Procon MO | Weidmüller ConCept | Wieland revos FLEX
>>>
Our pneumatic AirLiquid PN-Module has been improved for use with liquids. Sealing material is
Industrial viton (FKM / Fluorcarbon rubber) providing high resitance against heat aswell as oils, gasoline, diesel, biodiesel or ethanol. The Module is available with one or two pneumatic nipples. Brass-valves, locked on socket side, ensure reliability, efficiency and high mechanical firmness within the durable industrial environment. An operating-pressure range of up to 10 bar (145 psi) means a solid and lasting performance for your application. >
Hinweis
systemfeatures
note
operating pressure range up to 10 bar (145 psi)operating path of 4 mmlocked on one side (TwinValve locked on both)high mechanical firmnesshigh temperature resistance Viton-sealing (FKM / Fluorcarbon rubber) >
customer advantage Version PushPull
one or two pneumatic niples The PushPull PN-Module’s technical abilities equal the AirLiquid PN-Module but provides a push/pull-mechanism for rapid assembly/disassembly of the hose. timesaving assembly and quick start of operationeasy to service and maintainno special tools required >
Version Twinvalve
The TwinValve PN-Module’s technical abilities equal the AirLiquid PN-Module but provide locked valves (
check valves) on both sides of the pneumatic connection stopping the flow when disconnected. >
technical specifications
insulation materialtesting pressure valvestemperature rangehose connector (tube inner diameter)valve materialnominal sizesealing material
35 bar (508 psi)-20°C to +100°C2.5 mm (other on request)PA6.6 fiberglas strenghened | UL94-VObrass Ms582.5 or 4 mmViton (FKM) on request also NBR or EPDMoperating pressure10 bar (145 psi) >
Attention - security Note
When processing conducting or combustible liquids or gases by pneumatic modules be sure that under no circumstances there are electrical modules mounted within the same connector housing. >