You may also be interested in
Process indicator, Bourdon tube pressure gauge, Lockout relay, Dial thermometer, Manifold
Text version of the page
BPXPROGRAMMABLE CONVERTER TRIP AMPLIFIERFUNCTION CERTIFICATIONSProgrammable converter for measurement signals with easy programming by ProgressXmanager software (RS 232 connection). EMC EN 61326 and IEC 61000-6-2 Low Voltage Directive IEC 1010-1 overvoltage category II Intrinsic Safety EN 50014 / EN 50020 [EEx ia] IIC or [EEx ia] IELECTRICAL DATALCIE 03 ATEX 6469 X Number of channels 98 to 255 Vac (48 to 62 Hz) 21 to 53 Vdc (to specify when ordering) Front face green LED ON when energized. 1 ATEX Classification CE 0081 II (1) G/D or I (M1) Power supply Consumption 4 VASAFETY PARAMETERSInput signal (from hazardous area) see table here after (to safe area) Inputs Output signal Depending on option, 1 or 2 analog outputs and / or 2 or 4 alarm relays Input faults may be viewed on relays and on output signal (adjustable between 3.5 and 23 mA) On front face a RS 232 connector allows communication with P.C.Transmitter mV-V-TC-RTD100-Pot (Z - X) Current (X - T) (W - U - S - R - P - T) Voltage Uo (V) 27.9 0.057 7 Current Io (mA) 78.2 2.82 5.64 Power Po (mW) 545.47 0.04 9.87 External capacity group IIC (µF) 0.084 1000 15.7 External inductance group IIC (mH) 2.8 100 100 External capacity group IIB (µF) Galvanic isolation between IS inputs / power supply – NIS outputs 2500 Vac 50Hz Power supply / NIS outputs 1000 Vac 50Hz 0.654 1000 300 External inductance group IIB (mH) 4.2 150 150 MECHANICAL DATA ANALOGUE OUTPUTSInstallation Output current In safe area from 3.5 to 23 mA according to option Presentation ABS housing Wiring identical in generator or receiver mode Weight 200 g Max load resistance 750 (models with HART communication need at least 250 Storage temperature - 25 to 70 °C minimum load) Working temperature - 20 to 60 °C Relative humidity 5 to 95% without condensing Connection By cage clamps terminalsRELAY OUTPUTSMounting On rail EN 50022 Max current rating Codes OC or OF 250V - 3 A - 100 VA Other codes 250V - 5 A - 100 VAINPUT TYPESInput type Scale Accuracy (% of full scale ) Input impedance Characteristics Current (mA) -2.5 to + 23 mA 0.1 4 Voltage (mV) -10 to + 105 mV 0.1 > 1000 M Voltage (V) -1 to + 10.5 V 0.1 1 M Thermocouple J -210 to + 1200 °C Thermocouple K -250 to + 1372 °C Thermocouple B + 400 to + 1820 °C Thermocouple R -50 to + 1768 °C Thermocouple S Cold junction compensation adds ± 1°C max. extra error -50 to + 1768 °C >1000 M Thermocouple T -250 to + 400 °C Thermocouple E Possibility to detect thermocouple's wire cut-off -250 to + 1000 °C Thermocouple N -240 to + 1300 °C Thermocouple W5 -20 to + 2320 °C 0.1 with junction reference to 0°C For type E, refer to ** Resistance RTD100 2-wires Resistance RTD100 3-wires 0.1 Measurement current : 0.5 mA Line influence : 2.5 °C / Resistance RTD100 4-wires -220 to -270 to + 850 °C + 1200°C* 2.5 °C / between 2 wires 2/3/4-wires transmitter + 3.5 to + 23 mA 0.1 4 Short circuit protection supply, Transmitter voltage > 16 V at 20 mA Hart model > 15 V at 20 mA Root extraction Potentiometer 0 to 100% 0.1 n/a Potentiometer between 1 K & 20 K* : Liquid Hydrogen application ** : For thermocouple E : +/-10°C accuracy between -270 and -250°C, <0.1% for -250 to 1000°CFC-BPX-EN-20-06-2007 Subject to modifications due to technical advances Soucieux d'améliorer nos produits, nous nous réservons le droit de réviser sans préavis les caractéristiques de nos produits GEORGIN France Tel : 33 (0)1 46 12 60 00 Fax : 33 (0)1 47 35 93 98 regulateurs@georgin.com GEORGIN Belgium Tel : 02 735 54 75 Fax : 02 735 16 79 info@georgin.be |
|