process transmitter FKG series - 1

DATA SHEET The Pro c e s s X pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. FEATURES 1. High accuracy up to ±0.04% 0.065% accuracy as standard, 0.04% accuracy as option. Georgin’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The “Advance Floating Cell” design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. Georgin/HART® bilingual communications protocol ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX 4. Application flexibility Various options that render the ProcessX suitable for almost any process applications include: – Full range of hazardous area approvals – Built-in RFI filter and lightning arrester – 5-digit LCD meter with engineering unit – Stainless steel electronics housing 5. Burnout current flexibility (Under Scale: 3.2 to 4.0mA, Over Scale: 20.0 to 22.5mA) Burnout signal level is adjustable using Model FXW Hand Held Communicator (HHC) to comply with NAMUR NE43. 6. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. GEORGIN France GEORGIN Belgique Functional specifications Type: FKG : Smart, 4-20mA cc + Georgin/Hart® digital signal Service: Liquid, gas, or vapour Span, range and overrange limit: Type F KG 01 FKG 02 FKG 03 FKG 04 FKG 05 Lower limit Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. – Lower range limit (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor: 66kPa abs (500mmHg abs) at below 60°C regulateurs@georgin.com info@georgin.be

Open the catalog to page 1
process transmitter FKG series - 2

Output signal: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal. Power supply: Transmitter operates on 10.5V to 45V DC at transmitter terminals. 10.5V to 32V DC for the units with optional arrester. Load limitations: see figure below Load resistance Factory Mutual (pending) Operating area Note: For communication with HHC(1) (Model: FXW), min. of 250 W required. Hazardous locations: Authority (Digit 10= ) ATEX (K) Factory Mutual (pending) IECEx Intrinsic safety Ex II 1 G Ex ia IIC T5 (-40°C ≤ Ta ≤ +50 °C) Ex ia IIC T4 (-40°C ≤ Ta ≤ +70 °C) IP66/67 Entity Parameters: Ui ≤...

Open the catalog to page 2
process transmitter FKG series - 3

Zero/span adjustment: Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code “L, P, Q, S”). Damping: Adjustable from HHC or local adjustment unit with LCD display. The time constant is adjustable between 0 to 32 seconds. Zero elevation/suppression: Zero can be elevated or suppressed within the specified range limit of each sensor model. Normal/reverse action: Selectable from HHC(1). Indication: Analog indicator or 5-digit LCD meter, as specified. Burnout direction: Selectable...

Open the catalog to page 3
process transmitter FKG series - 4

Mounting position effect: Zero shift, less than 0.1kPa {1m bar} for a 10° tilt in any plane. No effect on span. This error can be corrected by adjusting Zero. Vibration effect: < ±0,25% Of spans for spans greater than 1/10 of URL. Frequency 10 to 150Hz, acceleration 39,2m/sec2 Material fatigue: Please consult Georgin. Dielectric strength: 500V AC, 50/60Hz 1 min., between circuit and earth. Insulation resistance: More than 100MW at 500V DC. Internal resistance for external field indicator: 12W max (connected to test terminal CK+ and CK-) Physical specifications Electrical connections: 1/2-14...

Open the catalog to page 4
process transmitter FKG series - 5

Smart, 4-20 mAdc + Georgin/Hart® digital signal Connections Process connection Oval flange connect. Electrical connection Range & wetted parts material Measuring diaphragm Wetted cell body Monel lining Gold coat Tantalum lining PVDF insert PVDF insert Monel lining PVDF insert Tantalum lining Monel lining Monel lining Tantalum lining Tantalum lining Monel lining Gold coat Tantalum lining Process cover PVDF insert Monel lining PVDF insert PVDF insert Tantalum lining Hast. C lining Monel lining Monel lining Tantalum lining Tantalum lining Monel lining Gold coat Tantalum lining PVDF insert...

Open the catalog to page 5
process transmitter FKG series - 6

DESCRIPTION Side vent/drain & mounting bracket Side Special applications & fill fluid Treatment Fill fluid Oxygen service Chlorine service Fluorinated oil (only w/digit 7=H,T,B,U) Vacuum service Process cover gasket - PTFE square section gasket in SS flange (*5) PTFE square section gasket in PVDF insert Bolts/screws material A Carbon steel Cr-Mo (standard) M10 (*9) Carbon steel Cr-Mo (standard) M12 for static pressure > 160 bar (*9) SS 630/304 (bolt/nuts) M12 for static pressure > 160 bar (*9, 10) SS 660/660 (bolt/nuts) M12 for static pressure > 160 bar Special options or design Special, no...

Open the catalog to page 6
process transmitter FKG series - 7

OUTLINE DIAGRAM (Unit:mm) <7th digit code: V, H, M, T> Earth terminal Oval flange screw IN CASE OF 4TH DIGIT CODE T Pipe Mounting

Open the catalog to page 7
process transmitter FKG series - 8

OUTLINE DIAGRAM (Unit:mm) 4th of code symbols "R, T, V, W, X" type is not attached Earth terminal GEORGIN France GEORGIN Belgique regulateurs@georgin.com info@georgin.be

Open the catalog to page 8

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52500

    2 Pages

  19. GC 52100

    2 Pages

  20. GB 64000

    2 Pages

  21. fc-pn

    48 Pages

  22. fc-gc6rfbg

    2 Pages

  23. fc-fm

    39 Pages

  24. A3300-31/51

    2 Pages