process transmitter FKC series
10Pages

{{requestButtons}}

Catalog excerpts

process transmitter FKC series - 1

FKC""5 Differential pressure (flow) transmitter Safety for Industrial Process The ProcessX differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined capacitance silicon sensor with state- of-the-art microprocessor technology to provide exceptional performance and functionality. 0.065% accuracy as standard, 0.04% accuracy as option. Georgin's micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 2. Minimum environmental influence The "Advanced Floating Cell" design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. GEORGIN//HART™ bilingual communication protocol The communication module is "bilingual" to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX series transmitters Various options that render the ProcessX suitable for almost any process applications include: • Full range of hazardous location approvals • Built-in RFI filter and lightning arrester • 5-digits LCD meter with engineering unit • Stainless steel electronics housing • Wide selection of materials 5. Programmable output Linearization Function In addition to Linear and Square Root, output signal can (Up to 14 compensated points at approximation.). 6. Burnout current flexibility (Under Scale: 3.2 to Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with 7. Dry calibration without reference pressure Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level FKC: Smart, 4-20mA DC + Georgin/Hart® digital signal Static pressure, span, and range limit: Static pressure Range limit Remark: To minimize environmental influence, span should be greater than 1/40 of the max. span in most Important*: Max possible overload pressure on LP side must be Lower limit of static pressure (vacuum limit) ; Silicone fill sensor: See Fig. 1 Fluorinated fill sensor:

Open the catalog to page 1
process transmitter FKC series - 2

FKC""5 Differential pressure (flow) transmitter Safety for Industrial Process OVERRANGE LIMIT! To maximum static pressure. OUTPUT SIGNAL: 4-20 mA DC (linear or square root) with digital signal POWER SUPPLY: Transmitter operates on 10.5V to 45V DC at transmitter 10.5V to 32V DC for the units with optional arrester. LOAD LIMITATIONS: see figure below Temp Code T4 Tamb mas = ■ 70'C Fruity Parameters' Vrnan - Ht Vdc, linn ■ S4.3 mA, Itmto* 0.06 W Ci = JW rfOFi ril" fnf mndeH withAMrhnul Arre^rf r Li - 0.7 mHK).6 mH Iw models wrffiAmttiout Analog Indicalm Electrical ratings Moticl Without...

Open the catalog to page 2
process transmitter FKC series - 3

Differential pressure (flow) transmitter ZERO/SPAN ADJUSTMENT: Zero and span are adjustable either from the HHC (1) or externally from the adjustment screw(span adjustment is not available with 9th digit code “L, P, M, Q, S, N”). DAMPING: Adjustable from HHC(1) or local adjustment unit with LCD display. The time constant is adjustable between 0 to 32 seconds. NORMAL/REVERSE ACTION: Selectable from HHC(1). INDICATION: Analog Indicator or 5-digit LCD meter, as specified. BURNOUT DIRECTION: (Selectable from HHC(1)) If self-diagnostic detect transmitter failure, the analog signal will be driven...

Open the catalog to page 3
process transmitter FKC series - 4

Differential pressure (flow) transmitter PERFORMANCE SPECIFICATIONS FOR LINEAR OUTPUT OVERRANGE EFFECT: Reference conditions, silicone oil fill, 316SS isolating diaphragms, 4 to 20mA analog output in linear mode ACCURACY RATING: (including linearity, hysteresis, and repeatability) Max span 32kPa models and above: For spans > than 1/10 of URL: ±0.065% of span or ±0.04% of span (optional) For spans < than 1/10 of URL: 0.1 x URL ± (0.015 + 0.05 ) % of span span Max span 20MPa models: For spans ≥ than 5MPa : ±0.1% of span For spans < than 5MPa : 5MPa span UPDATE RATE: 60 msec RESPONSE TIME: (at...

Open the catalog to page 4
process transmitter FKC series - 5

Differential pressure (flow) transmitter PERFORMANCE SPECIFICATIONS FOR SQUARE ROOT OUTPUT ACCURACY RATING: Output signal PROCESS CONNECTIONS: Output signal TEMPERATURE EFFECT: Effect per 28°C change between the limits of -40°C and +85°C “1” and “2” 1/4"-18 NPT, on 54mm centers, as specified. Meets DIN 19213. Option: 1/2”-14 NPT for oval flanges PROCESS-WETTED PARTS MATERIAL: Range code PHYSICAL SPECIFICATIONS Shift at 20% output signal ± (0.375 + 0.25 ± (0.24 + 0.03125 LOW FLOW CUT-OFF: Customer configurable for any point between 0 to 20% of output Process cover Wetted sensor body coating...

Open the catalog to page 5
process transmitter FKC series - 6

FKC""5 Differential pressure (flow) transmitter A plug-in analog indicator. An optional 5 digits LCD meter with engineering unit is also LOCAL CONFIGURATOR WITH LCD DISPLAY: An optional 5 digits LCD meter with 3 push buttons can support items as using communication with HHC1). A built-in arrester protects the electronics from lightning Lightning surge immunity: 4KV (1.2x50us). OXYGEN SERVICE: Special cleaning procedures are followed throughout the process to maintain all process wetted parts oil free. The fill fluid is fluorinated oil. CHLORINE SERVICE: The fill fluid is fluorinated oil....

Open the catalog to page 6
process transmitter FKC series - 7

FKC""5 Differential pressure (flow) transmitter Safety for Industrial Process OUTLINE DIAGRAM (UNIT:MM) Earth terminal Oval flange screw Side vent IN CASE OF 4TH DIGIT CODE T adjustment screw NOTE1) IN CASE OF 10TH CODE "C\ #11 CABLE IS SUTTBLE. NOTES) THE PRESSURE CONNECTOR IS LOCATED ON THE DOWN SIDE SURFACE OF THE DETECTOR. WHEN THE VENT/DRAINPLUG IS ATTATCHED ON THE UPPER SIDE OF THE DETECTOR (WHEN THE E1TH DIGIT OF THE CODE SYMBOLS ; C). NOTE3) WHEN THE ETTH DIGff OF THE CODE SYMBOLS "1.3,4" or THE 7TH DIGIT OF THE CODE SYMBOLS ■C.H.M.T

Open the catalog to page 7

All GEORGIN S.A. catalogs and technical brochures

  1. S5UI

    2 Pages

  2. GP Serie

    2 Pages

  3. GS/GSX

    2 Pages

  4. SR2 series

    2 Pages

  5. TR/TA.02

    2 Pages

  6. TR/TA.01

    2 Pages

  7. GR/GA

    2 Pages

  8. (D)MLFK

    2 Pages

  9. AIRGAS

    2 Pages

  10. U series

    2 Pages

  11. P Series

    16 Pages

  12. SG

    2 Pages

  13. BVL/M/NT(I)

    2 Pages

  14. BEKA's range

    182 Pages

  15. GN 25000

    2 Pages

  16. GN 21000

    2 Pages

  17. GH 11000

    2 Pages

  18. GC 52500

    2 Pages

  19. GC 52100

    2 Pages

  20. GB 64000

    2 Pages

  21. fc-pn

    48 Pages

  22. fc-gc6rfbg

    2 Pages

  23. fc-fm

    39 Pages

  24. A3300-31/51

    2 Pages