|
|
See other catalogues for General Cable
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | General Cable | | | | | | | | | | ications | | | | | | nica | | | | | | | | | | RFOC FRA950 RZ1MZ1-M | | | | | | | | | | armoured cable segurfoc fra 950 / fra-1 | | | | | | | | | | | | | | | | | | | | | | | | | GENERAL CABLE CODE | CROSS SECTION mm2 | NOMINAL DIAMETER UNDER ARMOUR | NOMINAL OVERAL DIAMETER | NOMINAL WEIGHT kg/km | BENDING RADIUS mm | MAXIMUM CURRENT RATING AIR 30°C A | VOLTAGE DROP Cos phi=0,8 A/V.km | MAX. DC RESISTANCE 20°C Ohms/km | SHORT CIRCUIT RATING (1 sec.] kA | | | | 7367114 | 1x50 | 12,3 | 18,5 | 760 | 185 | 193 | 0,804 | 0,3870 | 7,10 | | | | 7367115 | 1x70 | 14,0 | 20,2 | 990 | 205 | 246 | 0,587 | 0,2680 | 9,90 | | | | 7367116 | 1x95 | 15,8 | 22,2 | 1.280 | 225 | 298 | 0,448 | 0,1930 | 13,50 | | | | 7367117 | 1x120 | 17,6 | 24,0 | 1.545 | 240 | 345 | 0,374 | 0,1530 | 17,00 | | | | 7367118 | 1x150 | 19,8 | 26,4 | 1.840 | 265 | 399 | 0,323 | 0,1240 | 21,30 | | | | 7367119 | 1x185 | 21,6 | 28,4 | 2.250 | 285 | 457 | 0,276 | 0,0991 | 26,30 | | | | 7367120 | 1x240 | 24,5 | 31,3 | 2.840 | 315 | 539 | 0,232 | 0,0754 | 34,10 | | | | 7367121 | 1x300 | 27,1 | 34,1 | 3.475 | 345 | 619 | 0,202 | 0,0601 | 42,60 | | | | 7367122 | 1x400 | 30,6 | 37,8 | 4.475 | 380 | 741 | 0,178 | 0,0470 | 56,80 | | | | | | | | | | | | | | | | | | | | | | | | | armoured cable segurfoc fra 950 / ff | | | | | | | | | | | | | | | | | | | | | | | | | GENERAL | CROSS SECTION | NOMINAL DIAMETER UNDER ARMOUR | NOMINAL | NOMINAL WEIGHT | BENDING RADIUS | MAXIMUM CURRENT RATING | VOLTAGE | MAX. DC | CSIHROCURTIT RATING (1 sec.] | | | | CABLE | OVERAL | DROP | RESISTANCE | | | | CODE | DIAMETER | Cos phi=0,8 | 20°C | | | | | mm2 | mm | mm | kg/km | | | A/V.km | Ohms/km | kA | | | | | | | | | | | | | | | | | 7367206 | 2x1,5 | 8,6 | 13,2 | 340 | 135 | 26 | 21,505 | 12,1000 | 0,21 | | | | | | | | | | | | | | | | | 7367207 | 2x2,5 | 9,4 | 14,0 | 385 | 140 | 36 | 13,210 | 7,4100 | 0,36 | | | | | | | | | | | | | | | | | 7367208 | 2x4 | 10,3 | 14,9 | 450 | 150 | 50 | 8,255 | 4,6100 | 0,57 | | | | | | | | | | | | | | | | | 7367209 | 2x6 | 11,5 | 16,1 | 535 | 165 | 63 | 5,545 | 3,0800 | 0,85 | | | | | | | | | | | | | | | | | 7367210 | 2x10 | 13,2 | 18,0 | 665 | 180 | 87 | 3,330 | 1,8300 | 1,42 | | | | | | | | | | | | | | | | | 7367211 | 2x16 | 15,0 | 20,5 | 950 | 205 | 116 | 2,124 | 1,1500 | 2,27 | | | | | | | | | | | | | | | | | 7367212 | 2x25 | 18,0 | 23,7 | 1.290 | 240 | 135 | 1,376 | 0,7270 | 3,55 | | | | | | | | | | | | | | | | | 7367213 | 2x35 | 20,9 | 27,5 | 1.815 | 275 | 169 | 1,013 | 0,5240 | 4,97 | | | | 7368214 | 2x50 | 19,4 | 26,2 | 1.825 | 265 | 207 | 0,773 | 0,3870 | 7,10 | | | | | | | | | | | | | | | | | 7368215 | 2x70 | 22,1 | 29,1 | 2.350 | 295 | 268 | 0,560 | 0,2680 | 9,90 | | | | | | | | | | | | | | | | | 7368216 | 2x95 | 25,2 | 33,2 | 3.220 | 335 | 326 | 0,423 | 0,1930 | 13,50 | | | | | | | | | | | | | | | | | 7368217 | 2x120 | 27,9 | 36,1 | 3.855 | 365 | 383 | 0,351 | 0,1530 | 17,00 | | | | | | | | | | | | | | | | | 7368218 | 2x150 | 30,7 | 39,1 | 4.560 | 395 | 444 | 0,300 | 0,1240 | 21,30 | | | | 7368219 | 2x185 | 33,8 | 43,6 | 5.800 | 440 | 510 | 0,256 | 0,0991 | 26,30 | | | | 7368220 | 2x240 | 37,7 | 47,7 | 7.335 | 480 | 607 | 0,212 | 0,0754 | 34,10 | | | | 7368221 | 2x300 | 41,9 | 52,1 | 8.925 | 525 | 702 | 0,184 | 0,0601 | 42,60 | | | | 7368222 | 2x400 | 46,7 | 57,3 | 11.060 | 575 | 847 | 0,160 | 0,0470 | 56,80 | | | | | | | | | | | | | | | | | | | | | | | | | Installation Methods for current ratings In accordance with BS 7671 / IEE wirings Regulations. Minimum recommended installation Temperature: -5° | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|