Text version of the page
Optical Fibre CableMetallic armour for internal and external installations. LSZH sheathEC-794-1-E1, IEC-794-1-E4, IEC-794-1-E3, IEC-794-1-F5A, IEC-794-1-F1, IEC-794-1-E114 2 1 3 5CONSTRUCTION PHYSICAL CHARACTERISTICSSINGLE TUBE(up to 12 fibres)SINGLE TUBE(up to 12 fibres) 1 - Secondary 250”m loose fibres ValueStandard protection PBT tube Maximum pulling load 1500 NIEC-794-1-E1 2 - Tube filling Water repellent, non toxic, Impact strength 5 JIEC-794-1-E4 non irritant gel Maximum radial pressure 10 barIEC-794-1-E3 3 - Inner sheath Flame retardant,zero halogen, low smoke emission thermoplastic Static radial pressure 2 barIEC-794-1-E3 Water progression SheathsIEC-794-1-F5A compound Thermal cycling 20 șC to +70 șCIEC-794-1-F1 4 - Pulling Corrugated steel tape with Minimum bending radius 20 cmIEC-794-1-E11 element copolymer layer Cable weight 85 kg/km (approx.) 5 - Outer sheath Flame retardant,zero halogen,low smoke emission External diameter 10 mm (approx.) thermoplastic compoundMULTITUBE(> 12 fibres) ValueStandardMULTITUBE(> 12 fibres) Maximum pulling load 6500 NIEC-794-1-E1 Central element GRP rod Impact strength 5 JIEC-794-1-E4 1 - Secondary 250”m loose fibres Maximum radial pressure 10 barIEC-794-1-E3 protection PBT tube Static radial pressure 2 barIEC-794-1-E3 2 - Tube filling Water repellent, non toxic, Water progression SheathsIEC-794-1-F5A non irritant gel Thermal cycling 20 șC to +70 șCIEC-794-1-F1 Cable core Active and passive tubes wound around the central element,the spaces being filled with a water repellent Minimum bending radius 20 cmIEC-794-1-E11 Cable weight 190 kg/km (approx.) External diameter 14 mm (approx.) compound 3 - Inner sheath Flame retardant,zero halogen, low smoke emission thermoplasticCodeFibrescompoundC125HCHNGP12 C165HCHNGP16 Multimode 62,5/125 ”m4 - Pulling Corrugated steel tape with element copolymer layerC046HCHNGP4 C245HCHNGP24 C325HCHNGP325 - Outer sheath Flame retardant,zero halogen, low smoke emissionC066HCHNGP6C086HCHNGP8 C485HCHNGP48 C645HCHNGP64thermoplastic compoundC126HCHNGP12 C166HCHNGP16 CodeFibres C246HCHNGP24 C326HCHNGP32 Single mode 10/125 ”m C486HCHNGP48 C646HCHNGP64 C049HCHNGP4 CodeFibres C069HCHNGP6C089HCHNGP8 C129HCHNGP12 C169HCHNGP16 Multimode 50/125 ”m C045HCHNGP4 C249HCHNGP24 C329HCHNGP32 C065HCHNGP6C085HCHNGP8 C489HCHNGP48 C649HCHNGP64General Cable reserves the right to alter or modify the specifications and materials according to future technical development that may result in modifications to the technical data provided. Please contact your Customer Service Representative for latest information.49 |