3300 Series
Compact Low Pressure OEM Pressure Transmitters
► 15 - 250 psi pressure ranges (1 to 16 bar)
► Choice of outputs, electrical connections and pressure ports
► Operating temperature up to 257°F (125°C)
For OEMs that need consistent high levels of performance, reliability and stability the 3300 Series units offer a small package size with all stainless steel wetted parts at an unbeatable price performance ratio. A wide choice of electrical outputs as well as both electrical and pressure connections means the unit is suitable for most applications without modification. The compact construction of the 3300 series makes it ideal for installation where space is at a premium.
Specifications
Deutsch DT04-4P
DIN 9.4 mm
Performance
Long Term Drift
0.2% FS/YR (non-cumulative)
Accuracy
0.25% FS
Thermal Error
±0.1% FS/176°F (80°F)
Compensated Temperatures
-4°F to+212°F(-20°C to +100°C)
Operating Temperatures
-40°Fto +257°F(-40°C to+125°C)
Zero Tolerance
±0.5% of span, max.
Span Tolerance
±1% of span, max.
Fatigue Life
Designed for more than 100 M cycles
Mechanical Configuration
Pressure Port
See under "How to Order," last page
Wetted Parts
17-4 PH Stainless Steel
Electrical Connection
See under "How to Order," last page
Enclosure
IP67 (IP65 for electrical codes B and K)
Vibration
BSEN 60068-2-6 (FC)
BSEN 60068-2-64 (FH)
Shock
BSEN 60068-2-2n (Ea)
Approvals
CE, PED, RoHS
Weight
1.23 to 1.9 ounce (35 to 53 grams)
Individual Specifications
Voltage Output Units
Output
0 V min. to 10 V max.
See under "How to Order," last page
Supply Voltage (Vs)
3 Volts above full scale to 30 Vdc (24 Vdc, max. above
230°F (110°C) applications).
Source and Sinks 8mA
Current Output Units
Output
4-20 mA
Supply Voltage (Vs)
10-30 Vdc (24 Vdc, max. above 230°F (110°C) applications)
Ratiometric Output Units
Output
0.5 to 4.5 Vdc
Supply Voltage (Vs)
5 Vdc ±10%
Max Load Resistance
(Supply Voltage - 7.5) x 50 ohms
Packard MetriPack
EMC Specifications
Emissions Tests: EN61326-1:2006 and EN61326-2-3:2006
Test Standard
Test
EN55011:2007
Conducted Emissions
EN55011:2007
Radiated Emissions
Immunity Tests: EN61326-1:2006 and EN61326-2-3:2006
Test Standard
Test
EN61000-4-2:1995 + A1 + A2
Electrostatic Discharge
EN61000-4-3:2006
Radiated Immunity
EN61000-4-4:2004
Fast Burst Trasients
EN61000-4-6:2006
Conducted RF Immunity

pageCatalog pdf di En 2012-05-22-29