6700 Series-Stable Industrial Transmitters with Turndown Capabilities
► Gauge and Absolute Pressure Models
► Submersible, General Purpose and Wash down Enclosures
► High Stability Achieved by Sputtered Sensing Element
The 6700 series features customer accessible 5:1 turndown from nominal range via a switch and potentiometer. Down ranging whether factory or user adjusted is ideal for applications requiring high overpressure. The 6700 are housed in a rugged enclosure for harsh conditions and features superb stability by incorporating Gems CVD sensing element.
Specifications
Input
Pressure Range_0.5 to 400 bar; (7.5 to 6000 psi) Gauge and Absolute
Dimensions in. (mm) Max diameter 39mm, all models
Proof Pressure
2 x Full Scale (FS) (1.5 x FS for 400 bar, > 5000 psi)
Burst Pressure
>35 x FS < 100 psi (6 bar);
>20 x FS < 1000 psi (60 bar);
>5 x FS < 6000 psi (400 bar)
Fatigue Life
Designed for more than 100 million FS cycles
Performance
Output
4-20 mA (2 wire)
Supply Voltage (Vs)
9.5 to 40 VDC (ExII 1G 9.5 to 28 Vdc)
Supply Voltage Sensitivity
0.005% of max span/Volt
Long Term Drift
0.15% of max span/year (non-cumulative)
Accuracy
0.15% FS typical
Thermal Error Typical
15°F to 120°F (-10°C to +50°C) 0.5% of max span
-4°F to +176°F (-20°C to +80°C) 1% of max span
Operating Temperatures
-4°F to +185°F (-20°C to +85°C) elec. conn. code C G & L
-4°F to +122°F (-20°C to +50°c) elec. conn. code M, 3
-22°F to +212°F (-30°C to +100°C) process/media
Zero Tolerance
0.15 % span, typical
Span Tolerance
0.15% span, typical
Zero Adjustment
±10% (100% at factory) by potentiometer
Span Adjustment
17% to 100% of span by potentiometer/switches
Max. Loop Resistance
(Vs-9.5) x 50 ohms
Mechanical Configuration
Pressure Port
see ordering chart
Wetted Parts
17-4 PH Stainless Steel (1 & 1.6b 17-4 PH and 15-7 MO)
Electrical Connection
see ordering chart
Enclosure
318 Duplex SS, 17-4 PH SS
IP40 for gauge datum elec code C, L
IP65 for absolute datum elec code C, L
IP65 for elec. code G, 3
IP68 for elec. code M
Vibration
35g peak sinusoidal, 5 to 2000 Hz
Acceleration
100g steady acceleration in any direction 0.036% FS/g
for 10 psi (0.75 bar) range decreasing logarthmicaly
to 0.0007% FS/g for 6000 psi (400 bar) range.
Shock
Withstands free fall to IEC 68-2-32 procedure 1
Approvals
CE, Lloyds Register, optimal
Code c
-3.7" MAX-(94)
Six Pin Fixed Plug (10-6)
Code G
Fixed Plug to DIN 43650 Mating Connector Supplied Code L
Electrical Connector M12 x 1 (5 Pi
Code M
EXII 1G; E Exia II CT4 (-40°C < T amb <75°C)
Cert BASEEFA 02ATEX00040X_
approx. 250 grams (additional; cable 75 g/m)
Immersible to 200mWG Code 3
-3.82" MAX.-
(97)
1/2 - 14 NPT conduit
1-10