| | How To Order Use the Bold characters from the chart below to construct a product code. Please reference Notes. | |
| | | |
| | PS71 -10 -4MNZ -C -H -XX -XXXX | |
| | | |
| | | | | |
| | | |
| | 1 Pressure Range Code Insert Pressure Range Code from Table 1, below. 2 Pressure Fitting1 12L14 Zinc-Plated Steel -2MNZ = 1/8"NPTM -4MNZ = 1/4"NPTM -2MGZ = 1/8" BSPM (G type) -4MGZ = 1/4" BSPM (G type) -4MSZ = 7/16"-20 SAE Male -6MSZ = 9/16"-18 SAE Male 316 Stainless Steel -2MGS = 1/8" BSPM (G type) -4MNS = 1/4"NPTM -4MGS = 1/4" BSPM (G type) 3 Circuit -A=SPST/N.O. -B = SPST/N.C. -C = SPDT 4 Electrical Termination -SP=Spade Terminals2 -FLXX=Flying Leads3 -FLSXX=Flying Leads w/PVC Shrink Tubing3 -ELXX=1/2" NPT Male Conduit w/Flying Leads4 -CABXX = 18 AWG PVC Cable5 -H = DIN 43650A Male Half Only6 -HR=Right Angle DIN 43650A Male Half Only6 -HC=DIN 43650A 9mm Cable Clamp6 -HCR=Right Angle DIN 43650A 9mm Cable Clamp6 -HN = DIN 43650A with 1/2" Female NPT Conduit6 -HNR=Right Angle DIN 43650A with 1/2" Female NPT Conduit6 | 5 Options7 -V=Viton® Diaphragm -E=EPDM Diaphragm -N = Neoprene Diaphragm -10A = 10A @ 125/250 VAC Max. Rating -G = Gold Contacts (for loads less than 12 mA @ 12 VDC) -RD = Reduced Differential (25% reduction typical) -IP = Ingress Protection8 -OXY=Oxygen Cleaned9 -R=Restrictor (low damping coefficient) Brass -SR=Spiral Restrictor (high damping coefficient) 300 Series Stainless Steel10 -WF=Weather Pack Connector, Female -WM=Weather Pack Connector, Male -DE=Deutsch Connector, Male, DT04 Series 6 Fixed Set Point (optional) A. Specify set point -FS (in PSI or BAR, see example)11 B. Set Point Actuation R on Rising Pressure F on Falling Pressure Example: -FS2BARF for 2 BAR Falling or -FS20PSIR for 20 PSI Rising | Notes: 1. Other fittings available. Consult factory. 2. 20% increase in deadband typical. 3. 18" is standard. Specify lead length in inches (max. 48"). e.g. -FL18 or -FLS30. 4. 18" is standard. Specify lead length in inches (max. 48"). e.g. -EL18 or -EL30. 5. 36" is minimum. Specify cable length in inches. e.g. -CAB36or-CAB120. 6. DIN connectors require -C SPDT circuit. 7. Options -10A, -G or -RD cannot be combined. 8. Ingress Protection is available only with -FL, -FLS or -CAB Electrical Termination choices. Ingress Protection requires Fixed Set Point -FS. 9. Requires stainless steel housing. 10. -SR will result in wider deadbands and slower response time. 11. Set Point must be within Pressure Range selected in Step 1. | |
| | | | | |
| | Table 1 — Pressure Range Codes | |
| | | | | | | | | | | | | | | | | | | | ±1.5 psi (0.103 bar) +2% of setting | 3.5 psi (0.28 bar) +11% of setting | | | | | | ±2.5 psi (0.172 bar) +2% of setting | 3.5 psi (0.28 bar) +11% of setting | | | | | 65-300 psi (4.5-20.7 bar) | ±5.0 psi (0.345 bar) +2% of setting | 20 psig (1.38 bar) +11% of setting | | | | | 250-1000 psi (17.2-69.0 bar) | ±15 psi (1.03 bar) +2% of setting | 45 psig (3.10 bar) +12% of setting | | | | | 1000-3000 psi (69-206.8 bar) | ±30 psi (2.06 bar) +3% of setting | 70 psig (4.83 bar) +12% of setting | | | | | 2500-5000 psi (172.4-344.7 bar) | ±50 psi (3.45 bar) +4% of setting | 140 psi (9.65 bar) +13% of setting | | | | | | | | | | |
| | | |
| | | |
| | ' Repeatability and set point of units may change due to the effects of temperature. ' These numbers are for the standard microswitch. With either the -SP or -10A option, the values are typically 20% greater than those listed. With the -RD option, the values will be typically 25% less than those listed. In certain applications deadband can be tailored and controlled to customer specifications. Consult factory for details. | |
| | | |
| | Visit www.GemsSensars.com for most current information. | | |
| | | |
| | | | | | | | | |