Pressure Switch - GEMS SENSORS & CONTROLS - #28

/ 28


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
Pages:


See other catalogues for GEMS SENSORS & CONTROLS

Text version of the page
PS41 - Economical Miniature Pressure Switches
► 3.5 to 100 psi (0.24 to 7 bar)
These miniature pressure switches are designed for demanding applications where space and/or price are strong concerns. The switches utilize a piston/diaphragm design, which incorporates the high proof pressure of piston technology with the sensitivity of diaphragm designs. Switches are field adjustable via an Allen head screw that is hidden to protect against unauthorized tampering.
Specifications
Dimensions
Switch
SPST; SPDT
FLYING LEAD
3/32" or 1/8" ALLEN WRENCH ADJUSTMENT SCREW
01.10" (028)
Repeatability
See Table 1
Wetted Parts
Diaphragm Material
Nitrile (optional EPDM, Viton® or Neoprene)
Fitting
Brass (optional 316 Stainless Steel)
Electrical Termination
DIN 43650A IP65; Terminals IP00; Flying Leads IP65; Option IP: IP66; Conduit with Flying Leads IP65
PRESSURE PORT
_1.58"_ (40)
RED, NO. -GREEN, NC. BLACK, COM.
Proof Pressure
350 psi (24 bar)
Burst Pressure
700 psi (48 bar)
Approvals
CE, UL Approved units available
INGRESS PROTECTION OPTION (IP66) WITH FLYING LEADS FACTORY SET ONLY
01.25" (032)
Weight, Approximate
Brass: 0.3 lbs. (0.14 kg)
Recommended Operating Temperature Limits
Options Selected
Diaphragm Material
No option, -10A, -SP or -RD
-RD or -RD and -G
-SP or -10A
Nitrile
15°F to 185°F (-9°C to +85°C)
15°F to 250°F (-9°C to +121°C)
15°F to 212°F (-9°C to +100°C)
Viton®
0°F to 185°F (-18°C to +85°C)
0°F to 250°F (-18°C to +121°C)
0°F to 212°F (-18°C to +100°C)
EPDM
-10°F to +185°F (-23°C to +85°C)
-10°F to +250°F (-23°C to +121°C)
-10°F to +212°F (-23°C to +100°C)
Neoprene
-10°F to +185°F (-23°C to +85°C)
-10°F to +250°F (-23°C to +121°C)
-10°F to +212°F (-23°C to +100°C)
)IN 43650A - MALE HALF ONLY
DIN
43650A
1.10"
(28)
1.95"_ (50)
Note: Switches may function below the cold temperature limit but the set points and deadband will increase. Consult factory for details.
Electrical Switch Ratings
RIGHT ANGLE DIN (HNR)
ADJUSTMENT SCREW UNDER CAP SCREW
m
Options Selected
AC
DC
No option or -RD
5 amps @ 125/250 Volts
5 amps resistive, 3 amps inductive @ 28 Volts
-G or -RD with -G
1 amp @ 125 Volts
1 amp resistive, 0.5 amp inductive @ 28 Volts
-SP without -G
10.1 amps @ 125/250 Volts
-SP with -G
2 amps @ 125/250 Volts
m
I/)
DIN 43650-HNR-
PRESSURE PORT
m
B
2.80"
(71)
2.14"
(54)
1.12" AF l_ (28)
h9_

pageCatalog pdf di En 2012-02-07-13