| | How To Order Use the Bold characters from the chart below to construct a product code. Please reference Notes. | |
| | | |
| | PS41 -10 -4MNB -C -H -XX -XXXX | |
| | | |
| | | | | |
| | | |
| | 1 Pressure Range Code Insert Pressure Range Code from Table 1, below. 2 Pressure Fitting1 ~-2MNB=1/8"NPTM -4MNB = 1/4"NPTM -2MGB = 1/8" BSPM (G type) -4MGB = 1/4" BSPM (G type) -4MSB = 7/16"-20 SAE Male -6MSB = 9/16"-18 SAE Male 316 Stainless Steel -2MNS = 1/8"NPTM -4MNS = 1/4"NPTM -4MGS = 1/4" BSPM (G type) -4MSS = 7/16"-20 SAE Male 3 Circuit -A=SPST/N.O. -B = SPST/N.C. -C = SPDT 4 Electrical Termination -SP=Spade Terminals2 -FLXX=Flying Leads3 -FLSXX=Flying Leads w/PVC Shrink Tubing3 -ELXX=1/2" NPT Male Conduit w/Flying Leads4 -CABXX = 18 AWG PVC Cable5 -H = DIN 43650A Male Half Only6 -HR=Right Angle DIN 43650A Male Half Only6 -HC=DIN 43650A 9mm Cable Clamp6 -HCR=Right Angle DIN 43650A 9mm Cable Clamp6 -HN = DIN 43650A with 1/2" Female NPT Conduit6 -HNR=Right Angle DIN 43650A with 1/2" Female NPT Conduit6 | 5 Options7 -V=Viton® Diaphragm -N = Neoprene Diaphragm -E=EPDM Diaphragm -10A = 10A @ 125/250 VAC Max. Rating -G = Gold Contacts (for loads less than 12 mA @ 12 VDC) -RD = Reduced Differential (25% reduction typical) -IP = Ingress Protection8 -OXY=Oxygen Cleaned -WF=Weather Pack Connector, Female -WM=Weather Pack Connector, Male -DE=Deutsch Connector, Male, DT04 Series 6 Fixed Set Point (optional) A. Specify set point -FS (in PSI or BAR, see example)9 B. Set Point Actuation R on Rising Pressure F on Falling Pressure Example: -FS0.5BARF for 0.5 BAR Falling or -FS5PSIR for 5 PSI Rising | Notes: 1. Other fittings available. Consult factory. 2. Requires -10A or -G option. (20% increase in deadband typical) 3. 18" is standard. Specify lead length in inches (max. 48"). e.g. -FL18 or -FLS30. 4. 18" is standard. Specify lead length in inches (max. 48"). e.g. -EL18 or -EL30. 5. 36" is minimum. Specify cable length in inches. e.g. -CAB36or-CAB120. 6. DIN connectors require -C SPDT circuit. 7. Options -10A, -G or -RD cannot be combined. 8. Ingress Protection is available only with -FL, -FLS or -CAB Electrical Termination choices. Ingress Protection requires Fixed Set Point -FS. 9. Set Point must be within Pressure Range selected in Step 1. | |
| | | | | |
| | Table 1 — Pressure Range Codes | |
| | | | | | | | | | | | | | | | | | | 3.5-8 psi (0.24-0.55 bar) | ±0.35 psi (0.024 bar) +2% of setting | 1.50 psi (0.14 bar) +7% of setting | | | | | | ±0.8 psi (0.055 bar) +2% of setting | 3 psi (0.21 bar) +8% of setting | | | | | | ±2.0 psi (0.138 bar) +2% of setting | 5 psig (0.28 bar) +10% of setting | | | | | | | | | | |
| | | |
| | Repeatability and set point of units may change due to the effects of temperature. ' These numbers are for the standard microswitch. With either the -SP or -10A option, the values are typically 20% greater than those listed. With the -RD option, the values will be typically 25% less than those listed. In certain applications deadband can be tailored and controlled to customer specifications. Consult factory for details. | |
| | | |
| | Visit www.GemsSensars.com for most current information. | | |
| | | |
| | | | | | | | | |