Level Sensors - Continuous - GEMS SENSORS & CONTROLS - #19

/ 23


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
Pages:


See other catalogues for GEMS SENSORS & CONTROLS

Text version of the page
[*í Product Check List
860-747-4244
This is a □ Request for a Quote □ Order P.O.#_
Quantity Needed _
Name _
Photocopy This Form
Use one form for each product type you are selecting.
This form may also be completed online at gemssensors.com for RFQ.
Date Required / /
Shipping Method:_
Partials Accepted: □ Yes □ No
Fax ( )
Float Type Level Transmitters - XM/XT-800 Series
Application Environmental Conditions
CO OC LU I—
m
CO
< OC
This information is essential to the accurate and proper operation of your GEMS configurable sensors. Please complete fully and accurately.
1. Liquid Media:_
2. Pressure: Minimum _psig Maximum
3. Temperature: Minimum_°F Maximum
4. Specific Gravity: Minimum_ Maximum
5. Viscosity:
SSU
6. Tank Material: Tank Depth:
7. Unit is Mounted In: □ Tank Top □ Tank Bottom
8. Moisture Protection Required? □ Yes □ No
LU
Ol
1. Series:
□ XM/XT-800 (1/4" Resolution)
2. Mounting Type:
□ Type 1 (1/2" NPT) □ Type 2 (1-1/4" NPT) □ Type 3 (2" NPT)
□ Type 4 (3" 150# flange) □ Type 6 (2-1/2" sanitary flange)
4. Float Type1:
Match to Overall Length of Transmitter Stem
Ü
3. Materials:
a. Stem:
□ 316 Stainless Steel
□ Brass1
To 72 Inches
Over 72 Inches
□ 164255 - Buna N2
□ 69654 - Buna N
□ 43359 - Buna N
□ 52084 - Stainless Steel
□ 156490 - Stainless Steel
□ 43590 - Stainless Steel
Notes:
b. Mounting:
□ Brass1 □ 316 Stainless Steel
□ Carbon Steel (Type 4 flange only)
c. Collar Float Stops2:
□ Brass □ 316 Stainless Steel
Notes:
1. Type 1, Type 2 and Type 3 only
2. Standard Float Stops supplied in PH 15-7 MO on S.S. units and Beryllium Copper on Brass units. Brass and S.S. Float Stops with Brass and S.S. units only, respectively.
1. Stainless Steel float required for FM Approved Explosion Proof units.
2. Recommended for Type 2 mounting.
5. Dimensions:
Overall Length (complete one line only):
6. Input/Output:
a. Optional 24 VDC Power Supply:
□ 115 VAC input □ 230 VAC input
b. Signal Conditioners (XT-800 Series Only) Output Shown in Parenthesis:
□ 51965 (0-5 VDC - stem)
□ 51970 (0-12 VDC - stem)
□ 52536 (0-5 VDC - J-box)
□ 52537 (0-12 VDC - J-box)
□ 52555 (4-20 mA - J-box)
□ 120650 (0-5 VDC - panel mount)
□ 149600 (0-10 VDC - panel mount)
□ 112300 (4-20 mA - panel mount)
Float
Indicating Length
"C" Dimension
Float Factor X 1
Overall
Selected
(Half Inches)
±1/16" (1.8 mm)
Inch (mm)
Length
43359
+
+
2.5 (63.5)
=
43590
+
+
3.44 (87.3)
=
52084
+
+
3.63 (92.1)
=
69654
+
+
2.69 (68.3)
=
156490
+
+
2.06 (52.3)
=
164255
+
+
2 (50.8)
=
Notes:
1. Indicating Length: 1/2" Increments
2. Minimum C Dimension = 1/4"; or 1/2" on units greater than 72" In length.
7. Options:
□ Explosion Proof J-Box* □ NEMA 4 J-Box
* Required for FM Approved Explosion Proof units
Please contact Gems for any configuration or special requirements not covered on this form. 800-378-1600
0^
Gems Sensors & Controls
One Cowles Road Plainville, CT 06062-1198
tel 860.747.3000 fax 860.747.4244 www.gemssensors.com
Sensors & Controls
Quote: $_ Date Quoted:_

pageCatalog pdf di En 2012-05-19-08