| | FS-925 Series - General Purpose Flow Rate Settings: Liquids: 0.1 GPM to 1.5 GPM Air/Gases: See Flow Settings at right FS-926 Series - Low Flow Port Size: 1/4" NPT Primary Construction Material: Brass or Stainless Steel Setting Type: Fixed Flow Rate Settings: Liquids: 50-300 cc/min. Air/Gases: See Flow Settings at right | | U.L. Recognized — File No. E31926 CSA Listed — File No. LR30200 FM Approved — File No. 1H3A2.AX and 0A8A3AE | |
| | | |
| | These two series of precision-calibrated switches provides reliable and consistent performance; repeatability is within 1%. FS-925 and FS-926 units are factory preset for actuation at specified flow rates. These switches provide accurate detection of excessive or insufficient flow rates in such applications as: protecting against loss of fluid flow in hydraulic systems, assuring proper coolant flow in semiconductor processing equipment, monitoring high pressure lubrication systems, and ensuring proper air flow in water/waste systems. Specifications | |
| | | |
| | | | | | | | | | | | | | | Brass or 316 Stainless Steel | | | | | | | | | | Polysulfone for water; Brass for oil or air | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | With Brass or S.S. Piston | -20°F to +300°F (-29°C to +148.9°C) | | | | | -20°F to +225°F (-29°C to +107.2°C) | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | No. 18 AWG, 24" L., Polymeric Lead Wires | | | | | | | | Both the FS-925 and FS-926 use a spring-loaded piston to detect positive flow with great precision. They act upon direct fluid flow and will not show "false-positive" flow indication as can happen with sensors using indirect sensing methods such as pressure measurement. The FS-926 incorporates an additional lap-fitted piston for very low flows; see below. | |
| | | | |
| | | 9/32' DIA. (7.1 mm) MTG. HOLES (2) | |
| | | |
| | | |
| | | |
| | | |
| | *See "Electrical Data" on Page X-5 for more information. | | | |
| | | |
| | Double Piston Detects Minute Flow - FS-926 | | |
| | An additional, lap-fitted piston is used in Gems FS-926 Series to accurately detect low-flow rates. Calibration is determined by one or more metering holes in the end of the low-flow piston, which regulate bypass flow, and therefore the actuation setting. | | | |
| | | | |
| | Electrical Connection, 1/2" NPT C | |
| | | |
| | | |
| | When metered bypass flow is exceeded, the resultant pressure differential displaces the low-flow piston, moving the magnet carrier piston to actuate the reed switch. Two large bypass holes in the piston skirt are exposed after actuation to maintain low pressure drop. | | |
| | | |
| | | |
| | | |
| | | | | | | | | | |