CAN-Bus Tester 2 - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

CAN-Bus Tester 2 Features: Bus systems: – CAN, CANopen, DeviceNet, SAE J1939 Baud rates (5 kbit/s ... 1 Mbit/s) Measuring of the signal conditions: – General quality level (0 ... 100 %) – Disturbance-free voltage range – Rising and falling edges – Oscilloscope with message frame analysis Continuous monitoring Online trigger (real-time monitoring of the bus for logical and physical errors) User-friendly protocol monitor Testing of cables – Short-circuits, interruptions, loop resistances, cable length Straightforward application software: – Management of measurements (measurement types, measuring points, measuring times) – Comprehensive test record, broad variety of export functions – Automatic evaluation of the measurement results The CAN-Bus Tester 2 constitutes a universal measuring instrument for the commissioning, analysis, monitoring, troubleshooting and service/maintenance of CAN bus plants. Typical problems which occur during the operation of CAN bus plants, such as node failures, faults in the communication or complete standstill of the plant, often have their origins in the physical bus characteristics. The CAN-Bus Tester 2 provides an overview of the signal conditions on the bus, which helps you locate and rectify frequently occurring error causes without unnecessary delay. You can already ensure a correct bus cabling and verify its transmission properties when setting up the plant. You can also perform comparing measurements directly on the running plant over its life time and thus prevent downtimes. Fields of application: Commissioning of CAN bus plants Wiring test, module check Service/maintenance of CAN bus plants Troubleshooting and analysis of the physical bus characteristics Development of CAN modules Final testing in the production GEMAC - Gesellschaft für Mikroelektronikanwendung Chemnitz mbH Zwickauer Straße 227 D-09116 Chemnitz Tel.: +49 371 3377- 0 Fax: +49 371 3377- 272 www.gemac-chemnitz.de Seite: 1/2 Field Bus Testing Devices – Bus status, bus traffic load, error frame counter (active error/passive error)

 Open the catalogue to page 1

Technical Specifications*: General parameters and overview of functions Use (CAN type) CAN (ISO11898-2), CANopen, DeviceNet (EN 50325-2), SAE J1939 Baud rates All baud rates according to the particular CAN type; customized baud rates Quality level Signal quality level (0 ... 100 %) Disturbance-free voltage range and edges 0 ... 4 V, resolution 50 mV, edge steepness (in 1/64th of the bit width) Oscilloscope with message frame analysis 64-fold sampling per bit, 10,240 sample points, zooming, adjustable trigger position, recording of complete message frames, decoding to used protocol Bus status Bus...

 Open the catalogue to page 2

All GEMAC catalogues and technical brochures

  1. IS2XP010-U-EL

    3 Pages

    En
  2. IS2XP010-I-EL

    3 Pages

    En
  3. IS2SP090-C-BL

    2 Pages

    En
  4. IS2BP090-C-CL

    2 Pages

    En
  5. IS2TK090-O-RL

    2 Pages

    En
  6. IS1TK360-C-RL

    2 Pages

    En
  7. GC-CVC2.1

    4 Pages

    En

Archived catalogues

  1. Company profile

    1 Pages

    En