Geislinger Flexlink. - Geislinger - #4

/ 40


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
Pages:


See other catalogues for Geislinger

Text version of the page

Geislinger Flexlink

Coupling Designation

Example: GFL S 63 F 8A GFL: Geislinger Flexlink S: Series 63: Size F: Type 8: Number of links A: Axial support Technical data for each coupling can be selected from the technical data sheets depending on size, series and number of links.

Nominal Torque

T
KN The mean torque
T is calculated from the engine power
P and rotational speed
n

55.9 nPT

T mean torque kNm
P engine power kW
n rotational speed min
-1 The coupling size should be selected so that the coupling's nominal torque
T KN is greater or equal to the mean torque
T specified by the prime mover / application.
KN

TT

It is not recommended to choose an oversized coupling however, in combination with a Geislinger Coupling, the nominal torque of the Geislinger Flexlink should be equal or greater than that of the Geislinger torsional elastic Coupling

Permissible Vibratory Torque

T

v In addition to the static nominal torque
T KN , the coupling can also transmit a vibratory torque. The limits for vibratory torques
T v both under transient and continuous conditions are shown in diagram 1. Smaller engine mean torques
T allow for greater vibratory torques
T v . The limits shown in the diagram 1 should not be exceeded, not even during cylinder misfiring.
Geislinger GmbH, 5300 Hallwang, Austria Flexlink Catalog: Version 10.1 3 / 38

pageCatalog pdf di En 2012-05-19-11