| | Main technical | | tig | | |
| | | | L ■ | |
| | features | | | |
| | | | |
| | | | |
| | MODEL | AM | CC (a-b-c-d) | |
| | CLASS OF ACCURACY (*according to OIML R60) | 1% | 0.5% | |
| | DIVIsIONs | | | |
| | NOMINAL FULL SCALE LOAD (Ln) | 5...20KN | 750...1500KN | |
| | NOMINAL SENSITIVITY AT Ln (FSO) | 2mV/V | 2mV/V | |
| | SENSITIVITY TOLERANCE AT Ln % FSO | < ±5 | < ±1 | |
| | COMBINED ERROR % FSO (Non linearity / Histeresis / Repeatibility) | < ±1 | < ±0.5 | |
| | CREEP % FSO (After 30 mins at Ln) | < ±0.2 | < ±0.06 | |
| | ZERO BALANCE % FSO | < ±1 | < ±1 | |
| | CALIBRATION SIGNAL % FSO | | 80 ±1% | |
| | THERMAL DRIFT WITHIN Sensitivity | < ±0.02 | < ±0.02 | |
| | THE COMPENSATED RANGE Zero | < ±0.04 | < ±0.02 | |
| | % FSO °C Calibration | | < ±0.02 | |
| | ERROR FOR ECCENTRIC LOAD % FSO ON 400 x 400mm PLATFORM (with 1/3 Ln) | | | |
| | NOMINAL INPUT RESISTANCE | | | |
| | NOMINAL OUTPUT RESISTANCE | | | |
| | ISOLATION RESISTANCE | | | |
| | NOMINAL SUPPLY VOLTAGE | 10V | 10V | |
| | MAXIMUM SUPPLY VOLTAGE | 15V | 15V | |
| | COMPENSATED TEMPERATURE RANGE | -20...+50°C | -20...+50°C | |
| | OPERATING TEMPERATURE RANGE | -20...+60°C | -20...+60°C | |
| | STORAGE TEMPERATURE RANGE | -30...+80°C | -30...+80°C | |
| | PERMITTED LOAD | 130% Ln | 130% Ln | |
| | MAXIMUM APPLICABLE LOAD | 150% Ln | 150% Ln | |
| | RUPTURE LOAD | > 300% Ln | > 300% Ln | |
| | MAXIMUM ELASTIC DEFORMATION AT Ln | < 0.2mm | < 0.1mm | |
| | CLASS OF PROTECTION | IP65 | IP65 | |
| | Screened cable | 4 x 0.15 / 2m | VPT02A10-6PT2 | |
| | ELASTIC ELEMENT MATERIAL | Stainless steel | Stainless steel | |
| | | | | | |