Catalogue Load Cells
www.gefran.com
print switch display
Page / 8
GEFRAN - 145157, 131786, 4804
/ 8
See other catalogues for GEFRAN
Text version of the page
Main
technical features
MODEL
4^
OC
OD
CLASS OF ACCURACY (*according to OIML R60)
C1* C2* C3*
C1* C2* C3*
DIVIsIONs
1000 2000 3000
1000 2000 3000
NOMINAL FULL SCALE LOAD (Ln)
5...100Kg
6...15Kg
NOMINAL SENSITIVITY AT Ln (FSO)
2mV/V
2mV/V
SENSITIVITY TOLERANCE AT Ln % FSO
< ±10
< ±10
COMBINED ERROR % FSO
(Non linearity / Histeresis / Repeatibility)
C1 < ±0.05 C2 < ±0.03
C3 < ±0.017
C1 < ±0.05 C2 < ±0.03 C3 < ±0.03
CREEP % FSO (After 30 mins at Ln)
C1 < ±0.05 C2 < ±0.025
C3 < ±0.017
C1 < ±0.05 C2 < ±0.025 C3 < ±0.017
ZERO BALANCE % FSO
< ±10
< ±10
CALIBRATION SIGNAL % FSO
THERMAL DRIFT WITHIN Sensitivity
< ±0.003/0.0015/0.0015
< ±0.003/0.0015/0.0015
THE COMPENSATED RANGE Zero
< ±0.009/0.006/0.004
< ±0.009/0.006/0.004
% FSO °C Calibration
ERROR FOR ECCENTRIC LOAD % FSO ON 400 x 400mm PLATFORM (with 1/3 Ln)
< ±0.05 < ±0.03 < ±0.03
< ±0.05 < ±0.03 < ±0.03
NOMINAL INPUT RESISTANCE
420Q.
420Q.
NOMINAL OUTPUT RESISTANCE
350Q.
350Q.
ISOLATION RESISTANCE
> 10GQ.
> 10GQ.
NOMINAL SUPPLY VOLTAGE
10V
10V
MAXIMUM SUPPLY VOLTAGE
15V
15V
COMPENSATED TEMPERATURE RANGE
-10...+40°C
-10...+40°C
OPERATING TEMPERATURE RANGE
-20...+50°C
-20...+50°C
STORAGE TEMPERATURE RANGE
-25...+70°C
-25...+70°C
PERMITTED LOAD
100% Ln
100% Ln
MAXIMUM APPLICABLE LOAD
150% Ln
150% Ln
RUPTURE LOAD
MAXIMUM ELASTIC DEFORMATION AT Ln
< 0.5mm
< 0.5mm
CLASS OF PROTECTION
Test OIML R60
Test OIML R60
Screened cable
4 x 0.25 / 1m
4 x 0.25 / 1m
ELASTIC ELEMENT MATERIAL
Aluminium
Aluminium