| | | Alternating current and voltage alarm unit | | Alternating current and voltage alarm unit | | Pressure, force, position alarm unit | | |
| | | 48 x 48mm (1/16 DIN) / 96 x 48mm (1/8 DIN) | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | 0,2%f.s. ±1 digit (for 2/20Vac, 20/50mAac, 1Aac) 0,5% f.s. ±1 digit (for 200Vac, 500Vac, 5Aac) | | | | | | |
| | | | | | | | | |
| | | 0...20,0 sec + display hysteresis 0...9,9 scale points | | 0...20,0 sec + display hysteresis 0...9,9 scale points | | 0...20,0 sec + display hysteresis 0...9,9 scale points | | |
| | | Settable by user over entire scale range | | Settable by user over entire scale range | | Settable by user over entire scale range | | |
| | | Indicator of physical quantities -1999...+9999 (with or whitout decimal point) | | Indicator of physical quantities -1999...+9999 (with or whitout decimal point) | | Indicator of physical quantities -1999...+9999 (resolut. 1 digit) -19990...+99990 (resolut. 10 digit) Configurable decimal point position | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | Input from potentiometer (min 100П) powered by instrument 1,2Vdc possible linearization on 32 segments | | Input from potentiometer (min 100П) powered by instrument 1,2Vdc possible linearization on 32 segments | | |
| | | | | Autorange sensitivity 1,5...3,3mV/V possible linearization on 32 segments | | Autorange sensitivity 1,5...3,3mV/V possible linearization on 32 segments | | |
| | Direct non-isolated input or via - -transformer in voltage or AC | | |
| | 0...2/0...20/0...200/0...500Vac - -0...20/0...50/0...200mAac, 0...1/0...5Aac | | |
| | | | | | | | | |
| | | | | | | RS485, 1200...19200 baud MODBUS RTU, CENCAL GEFRAN | | |
| | | | | | | | |
| | | Optoisolated passive PNP Isolated 1500V | | Optoisolated passive PNP Isolated 1500V | | Optoisolated passive PNP Isolated 1500V | | |
| | | Tare zero, reset alarm latches, Hold, Flash | | Tare zero, reset alarm latches, Hold, Flash | | Tare zero, reset alarm latches, Hold, Flash | | |
| | | | | | | | | |
| | | max 5A, 250V resistive load coscp = 1 | | max 5A, 250V resistive load coscp = 1 | | max 5A, 250V resistive load cosp = 1 | | |
| | | | | Alarm units, alarms, on/off control | | Alarm units, alarms, on/off control | | |
| | | | | | | 24Vdc (10V min /20mA max) | | |
| | | | | Alarm units, alarms, on/off control | | Alarm units, alarms, on/off control | | |
| | | 24...240Vac ± 10% 3A max (for mod. 40A96 only) | | | | | | |
| | | | | | | | | |
| | | 4...20mA (R max 150Q) res. 12bit non isolated | | 4...20mA (R max 1500) res. 12bit non isolated | | 0..10V, 4..20mA (Rmax 5000) res.12bit non isolated | | |
| | | Retransmission of variable | | Retransmission of variable | | Retransmission of variable | | |
| | | | | 1,2Vdc for potentiometer 5-10Vdc/120mA; 15-24Vdc/50mA | | 1,2Vdc for potentiometer 5-10Vdc/120mA; 15-24Vdc/50mA | | |
| | | 11...27Vac/dc, 100...240Vac/dc; ±10% 50/60Hz | | 11...27Vac/dc, 100...240Vac/dc; ±10% 50/60Hz | | 11...27Vac/dc, 100...240Vac/dc; ±10% 50/60Hz | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | |
| | | | | | | | | |