Catalogue Uninterruptible Power Supplies (UPS)
www.geindustrial.com
print switch display
Page / 12
GE Uninterruptible Power Supplies (UPS) - 135187, 162580, 3574, 15006
/ 12
See other catalogues for GE Uninterruptible Power Supplies (UPS)
Text version of the page

Performance Characteristics

Energy E ffi ciency

UPS System E ffi ciency
( 500 k VA units operating at 50% and 100% load) The
GESGS eries is the most energy e ffi cient double conversion 950%100%
UPS in the industry and provides world-classenergy e GE 94.4%93.8% ffi ciency across the operating load range. Competitor A 91.5%92.0%
SG Series energy e ffi ciency is optimized for partial loadoperation and actually improves at part load operation. Most Competitor B 92.9%93.0%
UPS systems operate at part loads, not at full load,therefore the
UPS performance should be optimized andevaluated at part load operation.The optimization of the Competitor C 94.0%94.0%
SGS eries includes an input fi ltertunedfor part load operation and lower industrial inverter switching losses through space vector modulation inverter control.

Output Performance

Total Harmonic Distortion (THD)

A distorted output voltage waveform effects the proper functionof the load’s equipment. The

Input Performance

GEUPS has very low output voltage
THD , even with 100
% unbalanced or 100
% non-linear loads.

Robust Recti fi er for Wide Input Range Transient Response

The wide AC input voltage and frequency window avoidsunnecessary battery discharge even when operating from an unstable AC source (i.e. diesel generator). With the use of
SVM the
GEUPS can react very quickly tozero- 100
% step loads (within 1/3 cycle). This reduces theneed to oversize the UPS for severe pulse-load applications.

Programmable Soft Start Feature

0-30 seconds) eliminating in-rush current. Thisfeature reduces the need of oversizing the input power system (gen sets, feeder cables, overcurrent devices).

Voltage regulation

Allows the rectifier to ramp up in a programmable time period (
SVM enables the inverter to react very quickly under stepload conditions. As a result, the
GEUPS has very tight voltageregulation during step loads and 100
% phase-to-neutral(Ph-N) load imbalances.

Smart Input Filter Overload Capability on Inverter

GE offers an optional internal input filter with the
SGS eries
UPS . This “smart” filter has a programmable feature thatallows the filter to be switched off during start-up and low load conditions, improving e ffi ciency and input power factor. The
GEUPS has increased reliability due to overload andshort circuit withstand ability of the inverter. During severe overloads or short circuits the
UPS will transfer to bypassbefore destruction of the inverter.

Generator Compatibility

Output Performance Benchmark to the Competition Programmable features such as slew rate, phase anglerate-of-change and voltage rate-of-change allow the
UPS What is Condition GE Top 3 Competitors Better? to quickly sync to a genset during emergency back-up.
GE ’soptional input filter also has programmable features ensuring quick and continuous synchronization to generator voltage.
A B C Energy E ffi ciency (500kVA @ 50% Load) 94.4% 91.5% 92.9% 94.0% More Generator Friendly Voltage THD w/Linear Load < 2% 2% 4% 3% 2% Less GE PerformanceCompetition Voltage THD w/Non-linear Load <2% 2% 5% 5% 3% Less Overload Capability 150% > 1 min 60 S 30 s 10 s 10 s More +10%60 Hz-10%-20% 480 VAC +15% Voltage Transient Deviation for 100% Load Step < 3% 3% 5% 5% 5% Less Unbalanced Voltage Regulation 2% 3% 3% 3% Less GE PerformanceCompetition InputVoltage InputFrequency 3