Catalogue Safety Switches
www.geindustrial.com
print switch display
Page / 44
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
GE Switches & Disconnects - 3629, 208428
/ 44
See other catalogues for GE Switches & Disconnects
Text version of the page

Low Voltage Construction Fuses

Low Voltage Construction Fuses

GE Consumer and Industrial Fuse Program in partnership with Ferraz Shawmut
Contact your local GE Consumer and Industrial sales representative for fuse applications, specification, and sizing assistance. 250 and 600V RK1 T-D A2D and A6DFeatures and Benefits —Solid State SmartSpot Indicator—Time delay for motor starting and transformer inrush currents without nuisance opening—300kA interrupting rating - self-certified, UL witnessed tests—Low peak let-thru current—Easy 2-to-1 selectivity helps prevent nuisance shut downs and “black outs”—Rejection-style design deters replacement errors (when used with recommended fuse blocks)—Helps reduce inventory by taking the place of RK5, K, and H fuses—Metal-embossed date and product number for easier traceability and lasting identification—Fiberglass body provides dimensional stability in harsh industrial settings—Brass end-caps (blade-style) for cooler operation and superior performance Ratings —A2D—AC: 1/10 to 600A, 250 Vac, 200kA I.R. (self-certified for 250 Vac, 300kA I.R., UL witnessed)—A6D—AC: 1/10 to 600A, 600 Vac, 200kA I.R. (self-certified for 600 Vac, 300kA I.R.) 250 and 600V RK1 F-A A2K and A6KFeatures and Benefits
SAFETY SWITCHES —Rejection style design deters replacement by other fuse classes—Fiberglass body provides dimensional stability in harsh industrial environments—Easy-to-read imprint label for quick recognition and replacement—High degree of current limitation for low peak let-thru current

2

Ratings —A2K—AC: 1 to 600A, 250 Vac, 200kA I.R.—DC: 1 to 600A, 250 Vdc, 200kA I.R.—A6K—AC: 1 to 600A, 600 Vac, 200kA I.R.—DC: 1 to 600A, 300 Vdc, 200kA I.R. 250 and 600V RK5 T-D TR-R and TRS-RFeatures and Benefits —Solid State SmartSpot Indicator—Time delay for motor start-ups and transformer inrush currents without nuisance opening—Current limiting for low peak let-thru current—Rejection-style design deters replacement errors (when used with recommended fuse blocks)—Easy-to-read label for quick recognition and replacement—Metal-embossed date and product number for traceability and lasting identification—Fiberglass body provides dimensional stability in harsh industrial settings—Brass end-caps (blade-style) for cooler operation and superior performance—High-grade silica filler designed for fast arc quenching and high current limitation Ratings —TR—AC: 1/10 to 600A, 250 Vac, 200kA I.R.—DC: 1/10 to 2 8/10A and 35 to 400A, 250 Vdc, 20kA I.R.; 3 to 30A and 450 to 600A, 160 Vdc, 20kA I.R.—TRS—AC: 1/10 to 600A, 600 Vac, 200kA I.R.—DC: 1/10 to 12A, 600 Vdc, 20kA I.R.; 70 to 600A, 600 Vdc, 100kA I.R.; 15 to 60A, 300 Vdc, 20kA I.R.
SmartSpot, AmpTrap and UltraSafe are trademarks, and Tri-onic is a registered trademark of Ferraz Shawmut.

2-42BuyLog Catalogwww.geelectrical.com

Rev. 12/04 Prices and data subject to change without notice
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
pdf-page pdf di En 2008-12-49-04