Catalogue Safety Switches
www.geindustrial.com
print switch display
Page / 44
GE Switches & Disconnects - 3629
/ 44
See other catalogues for GE Switches & Disconnects
Text version of the page
Spec-Setter Safety switches
Quick Selection Guide
General Duty Safety Switch, Single-throw
UL Listed Fusing
Max. System Voltage
Ampere Rating
Switch Type
Class
Withstanding Rating (rms Sym Amps)
Enclosure Type
BuyLog Page
K
10,000
30­200
H
10,000
R
100,000
Fusible
K
10,000
400­600
H
10,000
250Vac
R
10,000
1
2-4,
250Vdc
K
10,000
3R
2-5
30­200
H
10,000
No1 _
R
100,000
Fu se
K
10,000
400­600
H
10,000
R
10,000
Heavy Duty Safety Switch, Single-throw
UL Listed Fusing
Max. System Voltage
Ampere Rating
Switch Type
Class
Withstanding Rating (rms Sym Amps)
Enclosure
Type
BuyLog Page
H
10,000
R
200,000
Fusible
J
200,000
1
600Vac
30-
L3
100,000
3R
2-6
through 2-16
250Vac
1200
H
10,000
- 4/4X
5,12
No1 _
R
10,000
Mill Duty
Fu se
J
10,000
L3
10,000
Double-throw Safety Switch
UL Listed Fusing
Max. System Voltage
Ampere Rating
Switch Type Class
Withstanding Rating (rms Sym Amps)
Enclosure
Type
BuyLog Page
600Vac 250Vdc
30­600
No Fuse
12 2-17 through 2-19
CO MJ
co
3
Non-fusible switch withstand ratings apply when protected by corresponding listed fuse type. 2100-200 amp also available as Type 3R (General Duty only).
3Class L fuses are only applicable when used with 800 and 1200A Type TC safety switches.
Enclosure Types
Type 1— Enclosures constructed for indoor use to pro vide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt.
Type 3R—Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure
Type — Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure.
Type 4X—Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure.
BuyLog Catalog
w w w. geelectrical.com
2-2
Rev. 12/04
Prices and data subject to change without notice
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44