Spec-Setter Safety Switches
Quick Selection Guide
General Duty Safety Switch, Single-throw
UL Listed Fusing
Max. System Voltage
Ampere Rating
Switch Type
Class
Withstanding Rating (rms Sym Amps)
Enclosure Type
BuyLog Page
K
10,000
30­200
H
10,000
R
100,000
Fusible
K
10,000
400­600
H
10,000
250Vac
R
10,000
1
2-4,
250Vdc
K
10,000
3R
2-5
30­200
H
10,000
No1 _
R
100,000
Fu se
K
10,000
400­600
H
10,000
R
10,000
Heavy Duty Safety Switch, Single-throw
UL Listed Fusing
Max. System Voltage
Ampere Rating
Switch Type
Class
Withstanding Rating (rms Sym Amps)
Enclosure
Type
BuyLog Page
H
10,000
R
200,000
Fusible
J
200,000
1
600Vac
30-
L3
100,000
3R
2-6
through 2-16
250Vac
1200
H
10,000
- 4/4X
5,12
No1 _
R
10,000
Mill Duty
Fu se
J
10,000
L3
10,000
Double-throw Safety Switch
UL Listed Fusing
Max. System Voltage
Ampere Rating
Switch Type Class
Withstanding Rating (rms Sym Amps)
Enclosure
Type
BuyLog Page
600Vac 250Vdc
30­600
No Fuse
12 2-17 through 2-19
CO MJ
co
3
Non-fusible switch withstand ratings apply when protected by corresponding listed fuse type. 2100-200 amp also available as Type 3R (General Duty only).
3Class L fuses are only applicable when used with 800 and 1200A Type TC safety switches.
Enclosure Types
Type 1— Enclosures constructed for indoor use to pro vide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dirt.
Type 3R—Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure
Type — Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure.
Type 4X—Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, hose-directed water, and corrosion; and that will be undamaged by the external formation of ice on the enclosure.
BuyLog Catalog
w w w. geelectrical.com
2-2
Rev. 12/04
Prices and data subject to change without notice

pageCatalog pdf di En 2012-05-22-29