Standard s

Electromechanical systems that require redundancy and checking ofrelay contacts should use relays that are designed with mechanical linkages to provide a positive relation between normally open and normally closed contacts to check the contact operation. Solid-state devices do not have a mutually exclusive normally open - normally closed contact arrangement. Other methods must be used to monitor the performance of these devices.” Category 4: All conditions of B apply, but now single fault detection isimperative and calls for not only redundancy in the input and output devices, but also for self-checking and cross monitoring. Again dual channel controls are called for. Category 1: Category 3: All conditions of B apply, but the safety related systemmust use “well tried” principles and components, see 7.2.2 EN (TC114/JWG 6). All conditions of B apply, but the complete safety controlsystem shall be designed so that any single fault shall not lead to the loss of the safety function and where practical, the single fault shall be detected. This now calls for not only redundancy in the interface relay but also in the input devices, pointing to dual channel systems.

Risk Categories: European Standard EN-954-1

Category B: Category 2: Safety devices and control systems at a minimum must bedesigned, selected and assembled to meet the operational requirements of design limits and influence of the processed materials and other external influences. Most domestic appliances fall into this category, and providing the components are correctly specified (load, switching frequency, etc.), then no other special features are required. All conditions of B apply, but in addition the machine shallbe prevented from starting if a fault is detected on power up. This suggests the use of an interface relay with redundancy and self checking on energization. Single channel operation is permitted providing that the input devices (E Stop buttons, gate switches) are tested for operation on a regular basis. Requirement of the safety related control circuit to meet the various categories are listed in section 7 of EN 954-1, but in general their requirements are as follows:
4 GE Interlogix Industrial

1-800-247-9447

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-97