| | | Enclosure Temperature Range Environmental NEMA Rating Protection Class Response Time Life Cycles Lead Types/O.D. | | Nylon 6/6 -40°F to 180°F (-40°C to 80°C) Hermetically Sealed Contact Switch Encapsulated in Polyurethane 1, 2, 3, 4, 4X, 5, 6, 12, 12K IP 67 1msec; 10 msec (150VA) 100,000 Under Full Load; Up to 200,000,000 Under Dry Circuit 18/2 SJTOW (K) / 0.30" (0.76cm) 18/3 SJTOW (K) / 0.33" (0.84cm) 18/4 SJTOW (K) / 0.34" (0.86cm) All Models | | |
| | | Warning— Each electrical rating is an individual maximum and cannot be exceeded! 1 Configuration with actuator away from the switch 2 Proximity of ferrous materials usually reduces sense range — typically by 50%. The shape and type of material cause a wide diversity of effects. Testing is required to determine actual sense range for specific applications. 3 Rated at 3.0A for 6,000 cycles only. Other ratings are at 100,000 cycles. 4 Can withstand inrush surge up to 4 amps. Voltage Drop 1.5V, minimum switch current of 30mA. 5 SER25 — Maximum 25 switches in series, triac output. | | |