| | | Description GE Interlogix Industrial Hinge Operated Safety Switches utilize a rotating shaft to provide a positive means of turning the control power off should an access panel, door, gate, guard, etc. be rotated open during machine operation. The switch operating shaft is designed to be in line with the rotation point of the door and uses the opening force of the door to rotate the safety switch operating shaft. When the access panel, door, gate, guard, etc. is rotated to the "open" position, the normally closed contacts in the safety switch are mechanically forced open turning off the control power in the machine—disabling the machine. Since the switch contacts can only be closed when the shaft is rotated to the closed position, the machine cannot be re-started until the door, gate, guard, etc. is closed. | | |
| | | S m o A I C A | | |
| | | Co A TI m H < | | |
| | | |
| | | co I o X m co | | |
| | | |
| | | |
| | | General Specifications | | |
| | | |
| | | FR 695-1 /FR 995-1 | | |
| | | Enclosure Polymeric glass-reinforced, self-extinguishing, shockproof thermal-plastic providing double insulation Compliance | | |
| | | |
| | | 0.47"10.32" r 1.20cm _|081cm|_ | | |
| | | 1.31" T- 3.32cm 0.87" 2.20cm | | |
| | | |
| | | |
| | | 0.87" 2.20cm 0.94" 2.40cm | | |
| | | 73/23/CEE 93/68/CEE 89/392/CEE | | |
| | | Low Voltage Directive Directive Machinery Directive Conduit entry One entry | | |
| | | |
| | | 3.33" 8.47cm | | |
| | | 0.12" 0.30cm | | |
| | | |
| | | |
| | | |
| | | |
| | | 2.03" 5.15cm | | |
| | | 0.94" 2.40cm | | |
| | | PG 13.5 Order PIN | | |
| | | |
| | | |
| | | |
| | | adapter not furnished | | | IN12135 | | |
| | | |
| | | |
| | | Mechanical endurance | |
| | | |
| | | 1.20" 3.05cm | | |
| | | 1.20" 3.05cm | | |
| | | Life Cycle Operating temperature range | | 1 million operations - 13° to +175°F (-25° to +80° C) | | |
| | | |
| | | |
| | | |
| | | Standards Safety Switch is in compliance with standards: UL508, CSA C22-2 nr.14, CEI EN 60947-5-1, EN 292, EN 418, EN 1088, EN 60204, EN 60947-5-1, IEC 204, IEC 337-1, IEC 947-5-1, NFC 63-140, VDE 0113, VDE 0660, BG-GS-ET-15. Positive Break Contacts are in compliance with standards: CEI EN 60947-5-1, EN 60947-5-1, IEC 947-5-1, VDE 0660-206. | | |
| | | | | | | | | | 0° 5° | 347° | | | | 21-22 I 1 | 1 | | | | 13-14 1 1 1 | | | | 13° | | | | | 0° 5° | 355° | | | | 21-22 I I I 11-12 1 1 1 | | | | | | | | | |
| | | 1NO 13 2J + If 1NC 14 22 11 21 2NC f-f | | |
| | | |
| | | 12 22 | | |
| | | |
| | | |
| | | |
| | | IP 65 (according to IEC529) Captive with self-lifting pressure plates 4° to OPEN the normally closed contact 8° to CLOSE the normally open contact Switch is in the normal position when the door is CLOSED | | |
| | | Protection class Terminal Screws Door Operating Radius | | |
| | | closed contact I I opened contact I I | | |
| | | |
| | | |
| | | ® @ | | |
| | | |
| | | |
| | | | | | | | | | | Order Information | Electrical Specifications | | | | | Model Body Number Material | Contact1 Contact Operating Short Circuit Config. Voltage, Max. Protection, Max. | | | | FR 695-1 Thermal Plastic | 1 N.O. + 1 N.C. 600 VAC, 300 VDC3 10A fuse | | | | FR 995-1 Thermal Plastic | 2 N.C. 600 VAC, 300 VDC3 10A fuse | | | | | | | | | | |
| | | | | | | | | | | | Contact rating2 | | | | UL/CSA | 10A A600/Q3003 | | | | | | IEC | AC15 | DC13 | | | | | Volts | 250 400 500 | 24 125 | 250 | | | | Current (A) | 6 3 1 | 6 1.1 | 0.4 | | | | | | | | | | | |
| | | |
| | | |
| | | Warning— Each electrical rating is an individual maximum and cannot be exceeded! 1 Configuration with door/gate closed 2 POSITIVE DOUBLE BREAK CONTACTS. Electrically isolated contacts allow different voltages placed on contact poles. 3 UL508 | | |
| | | |
| | | 1-800-247-9447 | | |
| | | GE Interlogix Industrial | | 31 | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |