Mechanical SafetySwitches
General Description
S afety switches are used to detect the opening of
machine guard doors,gates or panels and to prevent physical access to dangerous areas of the
machine. S afety switches are designed to help deter tampering witheither the internal machine controls or guards while in an
unsafe condition.All mechanical
safety switches are equipped with positive openingcontacts that open any normally closed contacts to assure machine
shutdown when an unsafe condition is detected. S afety switches are furnished completely assembled, ready to mount tothe machine. >
MECHANICALSWITCHES Approvals
SAFETY According to European S tandard:EN 60947-5-1According to International S tandard:IEC 947-5-1According to U L S tandard:U L 50 8 >
Po s itive Opening C ontact s
In conformance with:IEC 337-1, IEC 947-5-1, VDE 0660-206 >
C la ss of Protection
IP65 to IP67 ( T ype 12 to T ype 4) >
International Approval s
IM Q CEVDEU L File Number E1317 8 7 C S AFile Number J L R936 8 2 >
How to read the part nu m ber
FR 692- D FD 993- F
Enclo s ure FR/FP/F S Plastic, one conduit entryFDMetal, one conduit entryFXPlastic, two conduit entries Operating Key D/F S traight KeyD1/F1Right Angle KeyD2/F2Jointed KeyD3/F3Adjustable Jointed Key C ontact s 61NO + 1NC92NC >