Safety Expansion Relay WithTime Delay Opening
INT-06 Series
Applications
•Adds 3 safe, time-delay outputs when used with G E safety relayIN >
INT SERIES T -03 or IN T -04• Maintains safety circuit integrity by providing feedback to IN >
INDUSTRIAL SAFETY RELAYS T -03 orIN S L T witches AC or DC loads• DIN rail or panel mount
• EDs indicate relay status -03 T -04 to inhibit machine restart in case of component failure•
Electrical isolation between input and output
• S afety Monitor Relay or IN T -04 Emergency- S top S afety Relay. T T he IN he time delay is adjustable from 1 to 25 seconds to allow for controlledstops for high inertia loads. T -06-024 or IN T -06-120 Expansion S afety Relay with T ime DelayOpening is intended for use as part of a safety circuit. It provides three
additional safe output contacts when used with the
IN >
Panel Mount Di m ensions
T he IN T -06 uses positive-guided relays along with feedback contacts tothe IN >
2.17"5.5c T -03 or IN T -04 safety relay to prevent machine start-up in theevent of a component failure.Input voltage to the IN >
m T -06 is switched thru the contacts of the IN T -03or IN T -04. If a component failure occurs, the feedback loop to theIN >
2.95"7.5c m T -03 or IN T -04 prevents machine restart. >
4.53"11.5c m 0.26"0.66c m 1.48"3.75c Slot for 35 mm m 2.46"6.25c DIN rail m ount m General Specifications Wiring Door Open Configuration
U L / T UVAll Models >
RESET
ASAFEAUX.BCD C ontrol Input s (X1, X2 & Y1, Y2 terminal s ) >
120 VAC
230 VAC60 VDCLOADS
FUSE Open-circuit voltage12VDC
Closed-circuit current<10mAMax. contact resistance30 Ohms S imultaneity500 ms typical Safe Output s (A,B/ C ,D/E,F terminal s ) >
L1L2
ASAFEAUX.BCD
X1 X2Y1Y2 –+ L1L212X1X2Y1Y2N.O.N.C. Voltage230 VAC/60VDCCurrent4A (resistive)Response timeON: <50 msOFF: adjustable from1 to 25 secondsFuse4A, 250V, 5 x 20 mm, F/ >
Ti m e Delay RelayINT-06 Safety monitor RelayINT-03 OUTPUTS OUTPUTS EF F1F2INT06WIR EFG T AUX. Signaling Output s (F1,F2 terminal s ) Voltage120 VAC/30VDC >
230 VAC60 VDC120 VAC30 VDCLOADS Current1A (resistive) >
Note: Transient protection is required across the load when switching an inductive load. Operation
A.With voltage applied to control inputs via IN T -03 or IN T -04 outputcontacts, relay energizes.B.With control voltage removed, relay de-energizes after selectedtime delay.C.If an internal failure has occurred, feedback loop will not closethereby disabling IN >
File E 122942U 9880128199003 T -03 or IN T -04. >
Order Infor m ationElectrical Specifications
Part Nu m berPower Input (L1.L2)Required Fuse INT-06-02424VDC ± 20%Fast Acting 1/4 A (250V, 5 x 20 mm F/T) INT-06-120120VAC+10%, - 20%, 50/60 Hz, 5VAFast Acting 80 m A (250V, 5 x 20 mm F/T) Warning— Each electrical rating is an individual m axi m u m and cannot be exceeded! 20 GE Interlogix Industrial 1-800-247-9447