Safety Expansion Relay

INT-05 Series

INDUSTRIAL SAFETY RELAYS

Applications

INT SERIES •Adds 3 safe outputs when used with S entrol safety relays IN T -03and IN T -04•Maintains safety circuit integrity by providing feedback to IN T -03 orIN S L witches AC or DC loads•DIN rail or panel mount • EDs indicate relay status T -04 to inhibit machine restart in case of component failure•Electrical isolation between input and output • T he IN T -05-024 or IN T -05-120 Expansion T -03 S afety Monitoring relay or IN S afety Relay is intended foruse as part of a safety circuit. It provides three additional safe output contacts when used with the IN T -04Emergency- S top S afety Relay. T he IN T -05 uses positive-guided relays along with feedback contacts tothe IN

Panel Mount Di m ensions

T -03 or IN T -04 safety relay to prevent machine start-up in theevent of a component failure.Voltage to the IN
2.17"5.5c m T -05 is switched thru the contacts of the IN T -03 orIN T -04. If a component failure occurs, the feedback loop to the IN T -03or IN T -04 prevents machine restart.
2.95"7.5c m 4.53"11.5c m 0.26"0.66c m 1.48"3.75c Slot for 35 mm m 2.46"6.25c DIN rail m ount m

General Specifications

U L / T UVAll Models

Wiring Door Open Configuration

C ontrol Input s (X1, X2 & Y1, Y2 terminal s ) Open-circuit voltage24VDCClosed-circuit current24mA Max. contact resistance30 Ohms
RESET ASAFEAUX.BCD S imultaneity500 ms typical
120 VAC 230 VAC60 VDCLOADS FUSE Safe Output s (A,B/ C ,D/E,F terminal s ) Voltage230 VAC/60VDCCurrent4A (resistive) Response timeON:< 40 ms, OFF:<30 msFuse4A, 250V, 5 x 20 mm, F/ T
L1L2 ASAFEAUX.BCD X1 X2Y1Y2 –+ L1L212X1X2Y1Y2N.O.N.C. AUX. Signaling Output s (F1,F2 terminal s )
Expansion RelayINT-05 Safety monitor RelayINT-03 Voltage120 VAC/30VDC
OUTPUTS OUTPUTS EF F1F2INT05WIR EFG Current1A (resistive)
Note: Transient protection is required across the load when switching an inductive load. 230 VAC60 VDC120 VAC30 VDCLOADS

Operation

A.With voltage applied to control inputs via IN T -03 or IN T -04 outputcontacts, relay energizesB.With control voltage removed, relay de-energizes C. If an internal failure has occurred, feedback loop will not closethereby disabling IN T -03 or IN T -04
File E 122942U 9880128199003

Order Infor m ationElectrical Specifications

Part Nu m berPower Input (L1.L2)Required Fuse INT-05-02424 VDC ± 15%Fast Acting 1/4 A (250V, 5 x 20 mm ,F/T) INT-05-120120 VAC+10%, - 20%, 50/60 Hz, 5VAFast Acting 80 m A (250V, 5 x 20 mm ,F/T) Warning— Each electrical rating is an individual m axi m u m and cannot be exceeded!

1-800-247-9447

GE Interlogix Industrial 19
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-97
pdf-page pdf di En 2008-10-41-08