You may also be interested in
Borescope, Fiberscope, Angle beam transducer, X-ray inspection machine, Imaging system
Text version of the page
GEInspectionTechnologies.com
GE
Inspection Technologies
Eddy Current
Digital | Eddy Current | Film | Testing Machines | Ultrasonics | X-ray
Hocking Vector 2d
Dual Frequency Industrial Eddy Current Inspection System
Operating Frequency
Normal: 10 Hz to 10 MHz
Rotary: 10 kHz to 2 MHz
Conductivity: 60 kHz
Display
LCD with LED backlight
Protected by hard coated acrylic window
480 x 320 pixel resolution
115 x 78 mm viewable area
Gain
Adjustable together or as independent X and Y control for ultra-precise setting
-8 dB to 96 dB overall in 0.1 dB steps
Input Gain selectable 0 dB or 14 dB
Probe Drive -8 dB, 0 dB, and +8 dB
Low and High Pass Filters
Low Pass: 3 Hz to 2 kHz in more than 2,000 steps
High Pass: DC to 1.99 kHz in more than 500 steps
Alarms
Alarm options are: + and - levels, sector and box gate, flashing LEDs, internal sounder
Phase
0 to 359.9 in 0.1 steps
Internal Data Storage
Capacity from up to 50 traces and 50 settings. 28-character alphanumeric names, plus time and date stamps. Dynamic data may be recorded
and replayed
Conductivity and Coating Thickness Measurement
Capable of measuring electrical conductivity of materials in the range from 1 to 110 % IACS
Coating thickness readings from 0 to 1.3 mm
(0 to 0.050”)
Probe Compatibility
Absolute locator (100 ohm impedance)
Absolute standard (50 ohm impedance)
Bridge
Reflection
Hocking, Staveley, Zetec, and Rohmann rotary drives
Hocking 60 kHz conductivity probe
Balance Load
Manual or automatic. Selection from 1.3, 8.2, 22, 47, 82, or 120 ěH
Outputs
Rear Panel Connectors
Probe 1, 12 way Lemo for normal, rotary, and conductivity probes
Probe 2, 12 way Lemo for normal and absolute load for probe 1
Probe ABS, BNC for absolute probe
Note: The connections of Probe 2 and PROBE ABS are in parallel with Probe 1.
VGA OUT, standard 15-pin VGA “D” connector
RS 232, 9-way “D” connector
Standard I/O, 15-way “D” connector for
analogue outputs;
Remote control inputs for Balance,
Freeze and Clear;
External LED and relay drive outputs
Outputs, BNC connectors for analogue outputs and remote control inputs
Note: The output BNC connectors are in parallel with the Standard I/O connector.
Power, 12-24 V DC at 2 A
Power Source
12 V, 5 A
PC Connectivity
Dedicated Windows software allows easy reporting
and printing
Languages
English, French, German, Spanish, Portuguese
Instrument Weight
3.5 kg (7.72 lbs)
Dimensions
With Case
Width: 249 mm
Depth: 308 mm
Height: 147 mm (with feet)
133 mm (without feet)
Without Case
Width: 213 mm
Depth: 260 mm
Height: 129 mm
Technical Data
© 2005 General Electric Company. All Rights Reserved. GEIT-50007US (05/05)
We reserve the right to technical modifications without prior notice.
Features
• Dual frequency, differential, and absolute modes through a single input
• Detects defects in many components regardless of shape complexity
• Determines hardness of parts and can trigger accept/reject gates
• Finds corrosion, erosion, fatigue, and cracks in non-ferrous pipes
• Results can be seen and interpreted in real time
• Applicable industries include automotive, power generation, tube/ pipe manufacture and metal manufacturing.
|
|