MiCOM Agile P54A/B
2Pages

{{requestButtons}}

Catalog excerpts

MiCOM Agile P54A/B - 1

Protection and Control • Excellent migration product when pilot wire protection is changed to fibre or multiplexed comms • Maximises connection of renewables for up to 6 line or cable ends • Full support of SONET/SDH channel switching • Suitable for direct fiber and multiplexed (IEEE C37.94) networks, including MPLS systems Application Flexibility • Ability to take an end off-line for maintenance • Back-up protection, reclosing, measurements and recording as per P141-P145 and P14N/D products - no need to retrain • Easy scheme customisation with programmable scheme logic and LEDs • Extensive binary signalling capability between ends for intertripping, breaker fail, interlocking and control/observation of remote 3rd party substations Advanced Communications Distribution Dual and Multi-Ended Current Differential Network Challenges - Economical Line Differential For many years the distribution networks have used pilot wire differential protection. Pilot wire line differential protection compares the currents entering and leaving the protected zone via a pair of pilot wires. As technology has advanced, copper pilot wires are being replaced by fibre links between substations, offering safer and higher bandwidth communications paths, with simpler inherent self-supervision. Also, as the distribution power networks evolve to transport power in evermore complex ring and multi-terminal networks, line/cable differential protection becomes increasingly attractive, with its inherent ability to address grading/selectivity challenges. Finally it offers scalability for multi-terminal circuits to accommodate many distributed generation connections or new load taps along the line. GE’s multi-ended current differential protection provides an excellent migration product when pilot wire protection is changed to fibre or multiplexed communications. The relays are ready for any protection topology from two to six terminals, whether those multiterminals exist now, or are provisioned for connection in the future. For distribution networks, two compact, economical models, P54A and P54B are available in a half rack 40TE case size. MiCOM Agile P54A/B Distribution Line/Cable Differential For applications where VT inputs are not available, or where simplicity is preferred, the P54A model is the perfect choice. The P54A backup protection operates non-directional. The sister P54B model has an additional 4 VT inputs to support autoreclose with check synchronization, and directionalised backup protection. Both models offer three-pole trippings. The P54A/B relays support IEC 61850 Edition 2, SNMP v3 and IEEE1588, opening deployment possibilities in today’s digital substations. PRP, HSR and RSTP redundant Ethernet station bus communications are also supported. V Compact Design (40TE, 8-inch design half rack) V Smaller CTs New CT saturation algorithm reduces CT requirements V Digital substation ready -IEC 61850 Edition 2, IEEE 1588 V Sub-cycle for 2-ended up to 4-ended schemes; 1.25 cycle for 5 and 6 ended schemes. Limits arcing time, assists DG ride-through V Reduced communications downtime PRP, HSR and RSTP redundant Ethernet station bus topologies V Flexible protection communications SONET/SDH, IEEE C37.94, direct fibre, MPLS ready • Advanced IEC 61850 Edition 2 implementation with IEEE1588 support • Wide range of supported protocols: Courier/K-Bus, IEC 60870-5-103, DNP 3.0 (EAI-485 or Ethernet) and IEC 61850

Open the catalog to page 1
MiCOM Agile P54A/B - 2

Backup Feeder Protection Highly-selective protection for overhead lines and underground cables with three phase tripping. Maximises connection of renewables or distribution tapped loads for up to 6 line or cable ends In addition to the differential protection, the P54A/B provide integrated feeder back-up protection in the same box. This make the P54A/B a perfect one box solution for economical distribution protection applications. Fast operating time, less than 1 cycle for up to 4 ends, 1.25 cycles for 5 or 6 ended Negative sequence overcurrent and SEF (0.5% In sensitivity) Economical - no...

Open the catalog to page 2

All GE Grid Solutions catalogs and technical brochures

  1. MIG

    3 Pages

  2. DTR

    4 Pages

  3. SPM

    8 Pages

  4. TOV

    3 Pages

  5. MIC

    2 Pages

  6. Multilin F60

    9 Pages

  7. MIG II

    8 Pages

  8. Model JVW-5C

    2 Pages

  9. Multilin T60

    9 Pages

  10. Multilin 489

    9 Pages

  11. MultiNet

    3 Pages

  12. iNET-II

    4 Pages

  13. Multilin L90

    10 Pages

  14. COSI

    2 Pages

  15. Reason DR60

    4 Pages

  16. Multilin 850

    4 Pages

  17. G650

    8 Pages

  18. Hydran M2

    2 Pages

  19. TN1U

    4 Pages

  20. Multilin 339

    16 Pages

  21. Multilin 469

    10 Pages

  22. Multilin A60

    6 Pages

  23. Multilin 350

    16 Pages

  24. Multilin F650

    12 Pages

  25. F35

    8 Pages

  26. 345

    12 Pages

  27. 745

    8 Pages

  28. Multilin G30

    9 Pages

  29. Multilin C30

    6 Pages

  30. Rectifier

    4 Pages

  31. RMIO

    2 Pages

  32. Multilin G60

    9 Pages

  33. Multilin D400

    12 Pages

  34. GL 107X

    2 Pages

  35. Disconnectors

    12 Pages

  36. CGVB-05

    2 Pages

  37. KOTEF

    4 Pages

  38. FK

    4 Pages

  39. B65

    4 Pages

  40. smorb

    3 Pages

  41. MIF II

    8 Pages

  42. SR family

    2 Pages

  43. 735/737

    4 Pages

  44. hid

    2 Pages

  45. dtp

    5 Pages

  46. M60

    8 Pages