Specifications and Ordering Information
200135 Dual Seal Leak flexiTIM™ Module and 200136 Seal Leak detection Transducer
Description
The Seal Leak flexiTIM™ System consists of the 200136 Seal Leak Detection Transducer and the 200135 Dual Seal Leak flexiTIM™ Module. The Seal Leak Detection Transducer utilizes a sensor detecting the position of a diaphragm to measure the gauge pressure. The Dual Seal Leak flexiTIM™ Module provides two channels of static pressure, conditions the signals and sends the information into the Trendmaster 2000 system to display the pressure readings. It is designed as a scanning system as part of the Trendmaster 2000 system to measure pressure changes primarily near the seals on tandem-seal or dual seal pumps. It can also be used on single seal pumps if there is an expected pressure increase near the sensor of greater than 5% of full scale in the event of a seal failure. The Seal Leak Detection Transducer has a robust design to increase its survivability in harsh environments. It is able to withstand an occasional 10.3 bar (150 psig) water jet at the rear of the sensor and on the transducer cable. Cable seal adapters or conduit fittings protect the connectors to enable the entire system to withstand condensing humidity. The system is designed to meet IP66 for moisture ingression. The Transducer is also designed to withstand extremely high pressures caused by valve or seal failures without any degradation of the diaphragm, returning to normal operation when the pressure is within the Transducer’s specified range. >
Specifications
Seal Leak flexiTIM >
TM System Operation outside the specified limits will result in false or inaccurate readings. Electrical & Mechanical Characteristics Measurement Range: 0 to 2.1 bar (0 to 30 psig) Full Scale Output: 2320 mV/bar (160 mV/psig) 10% (includes linearity, interchangeability, and repeatability error sources) Span: 0.11% F.S./ C ( 0.06% F.S./ F) over the compensated temperature range 0 C to 45 C (32 F to 113 F) 0.18% F.S./ C ( 0.10% F.S./ F) over the extended temperature range -18 20.7 bar (300 psig) 27.6 bar (400 psig) Complies with the European CE Mark C to 85 C (0 F to 185 F) Zero: Environmental Limits 0.12% F.S./ C ( 0.07% F.S./ F) as temperature varies from 25 C (77 F) over the extended temperature range. Resolution: 0.007 bar (0.1 psig) Proof Pressure Rating: Burst Pressure Rating: Classification: Operating Temperature: -35 C to 85 C (-31 F to 185 F) for the flexiTIM >
TM module See Environmental Limits for the Seal Leak Detection transducer >
For Reference Only – See Document #161736 Page 1 of 7