Text version of the page
200135 flexiTIM™ Module 200136 Transducer with integral cable Electrical & Mechanical Characteristics Electrical & Mechanical Characteristics Interchangeability: ±0.11 bar (±1.6 psig) Span: 0.03% F.S./ C ( 0.02% F.S./ F) over the temperature range -7 Housing Material: Polybutulene Terephthalate/ Polycarbonate 20% glass fiber blend. C to 93 C (20 F to 200 F) for wetted diaphragm Mass: 0.55 kg (1.2 lbm) not including fittings or conduit body Zero: 0.06% F.S./ C ( 0.03% F.S./ F) as temperature varies from 25 C (77 F) over -7 C to 93 C (20 F to 200 F) for wetted diaphragm Dimensions: See diagram Environmental Limits 100% condensing on exposed surfaces. Condensation on rear plate of flexiTIM Interchangeability: ±0.14 bar (±2.0 psig) Humidity: Transducer DC resistance: 8.73 0.70 ohms measured from center conductor to outer conductor
TM Module is not recommended. Designed to meet IP66 Minimum Cable Bend Radius: 25.4 mm (1 in) Enclosure: Electromagnetic Compatibility Cable Material: 75 ohm triaxial, fluoroethylene propylene (FEP) insulated Radiated Emissions: EN 55022 (1998), Class A. Tensile Strength (max rated): 330 N (75 lbf) Transducer case to Transducer lead to extension cable connectors. Electrostatic Discharge: EN 61000-4-2 (1995), Criteria A. Radiated Susceptibility: EN 61000-4-3 (1996), Criteria A. Construction: 3300 XL Probe viewing a 17-7 PH cond C stainless steel diaphragm, housed in a 304 stainless steel body. Conducted Susceptibility: ENV 50141 (1993), Criteria A. Connector: Gold plated brass nut, Gold plated Beryllium Copper body with PTFE dielectric insert Electrical Fast Transient: EN 61000-4-4 (1995), Criteria A. Magnetic Field: EN 61000-4-8 (1994), Criteria A. Environmental Limits Hazardous Area Approvals C to 149 C (0 F to 300 F) Ethylene Propylene: -18 C to 121 C (0 F to 250 North American: Div 2 Div 1 approvals expected second quarter 2003 Humidity: Enclosure: Operating Temperature: F) Fluids compatible with 17-7 PH cond C stainless steel, 304 stainless steel, and either Fluorocarbon or Ethylene Propylene, depending on O-Ring Material option (common applications shown below) European: Zone 0 approvals expected second quarter 2003 Installed without barriers per drawing 136926 Ex nA IIC, Class I, Zone 2 T Pressure Media: 100% condensing on exposed surfaces. Condensation on connector is not permitted. Designed to meet IP66 Dependent upon O-Ring Material Fluorocarbon: -18 Fluorocarbon: Ethylene Propylene: Molten sulfur, propane, ethane, naphtha, butylene, propylene, sulfuric acid, butane, fuel oil, natural gas, petroleum oil, and turbine oil Hydrogen sulfide, amine, caustic soda, MEA, ammonium hydroxide, carbon dioxide, chlorine, nitrogen, gaseous oxygen and steam
4 , T
a = 100 C Class I, Div 2, Groups A, B, C & D T
4 , T
a = 100 C
For Reference Only – See Document #161736 Page 2 of 7
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
pdf-page pdf di En 2008-10-41-12