Physical & Environmental EMC Directives Weight: 250 g (0.55 lbm) Sensor Head 150 g (0.33 lbm) Electrostatic Discharge: EN 61000-4-2, Criteria B Radiated Susceptibility: EN 61000-4-3, Criteria A Dimensions: See diagram Conducted Susceptibility: EN 61000-4-6, Criteria A Materials: Gold plated, per MIL-G-45204 Type III Grade A, C-276 welded to a 316L stainless steel body. (patent pending) Electrical Fast Transient: EN 61000-4-4, Criteria B Humidity: 95% condensing on exposed surfaces excluding connector Surge Capability: EN 61000-4-5, Criteria A Body: Designed to meet IP67 Dependent upon O-ring material North American: Magnetic Field: EN 61000-4-8, Criteria A Hazardous Area Approvals Operating Temperature: Ethylene Propylene Hifluor -40°C < Ta < 85°C AEx/Ex ia IIC T4 CLASS I, DIV 1, GROUPS A, B, C, D AEx/Ex nA T4 CLASS I, DIV 2, GROUPS A, B, C, D CSA 031481528/X II 1G EEx ia IIC T4 : -26 >
o C to 150 >
o C (-15 >
o F to 302 >
o F) >
: -40 >
o C to 150 >
o C (-40 >
o F to 302 >
o F) Pressure Media: Fluid media compatible with C-276 and either Hifluor European: or Ethylene Propylene o-ring material (common media below) O-rings LCIE 04ATEX6031X II 3G EEx nA II T4 LCIE 04ATEX6032X >
2 : B51 Pressure CRN: 0F1414_65 Hifluor Hydrogen sulfide, sulfuric acid, butane, fuel oil, petroleum oil, turbine oil, propane, propylene, butylenes, and natural gas. (black): Patents: pending Components or procedures defined in this patent apply to this product. Ethylene Propylene (purple): Ammonium hydroxide, anhydrous ammonia Mounting Torque: 68 N-m (50 lbf-ft) >
2 The o-ring utilized must be compatible with the type of gas or fluid that the transducer will be operated in. Consult your local Bently Nevada representative for additional assistance. For Reference Only – See Document #166815 Specifications and Ordering Information Page 3 of 7