Specifications
Operation outside the specified limits will result in false or inaccurate readings.
Transducer Characteristics: Measurement Range: psia 0 to 100/ 250/ 500/ 1000/ 2500/ 5000/ 10,000 bar 0 to 6.8/ 17/ 34.5/ 69/172/ 345/ 689 Proof (Over) Pressure: 1.5X Full Scale Burst Pressure: 3X Full Scale (2X FS on 689 bar/ 10,000 psia units) Full Scale Output: Vdc 10 0.3 Zero: Vdc 0.5 0.1 Power Supply: Vdc 18 to 30 Max. Current: mA 15 Compensated Temperature: >
o C -40 to 85 >
o F -40 to 185 -1.0 to +2.0 (for 6.8 and 17 bar/ 100 and 250 psia) Thermal zero shift >
1 : %FS -0.5 to +1.5 (for all other pressure ranges) Thermal sensitivity shift: See diagram Linearity, hysteresis, repeatability %FS 0.3 Frequency response: 0Hz to 5500 Hz 1 dB Operating Temperature: >
o C -40 to 85 (
electronics housing) >
o C -40 to 150 (sensor head) >
o F -40 to 185 (electronics housing) >
o F -40 to 302 (sensor head) >
1 Within compensated temperature range. For Reference Only – See Document #166815 Specifications and Ordering Information Page 2 of 7